MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2004.08.047

Медицинская библиотека · The Annals of thoracic surgery · 2005

The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.

Emery Robert W, Krogh Christopher C, Arom Kit V, Emery Ann M, Benyo-Albrecht Kathy, Joyce Lyle D, Nicoloff Demetre M

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

From October 1977 to October 2002, 4,480 patients (age range, 17 to 94 years; average, 64 +/- 13 years) underwent single valve replacement with the St. Jude Medical heart valve. Of 2,982 aortic (AVR) and 1,498 mitral valve replacements (MVR), concomitant coronary artery bypass grafting was performed on 42% and 33%, respectively.

METHODS

Cardiac Surgical Associates has maintained an independent database of patients having valve replacement with the St. Jude Medical prosthesis since the world's first implant. Patients were contacted by questionnaire or phone from November 2002 through June 2003. Hospital course and valve-related events were verified by patient chart review or physician contact.

RESULTS

Follow-up was 95% complete. Operative mortality was 4% with AVR and 9% with MVR. Total follow-up was 32,190 patient-years (range, 1 month to 24.8 years; average, 7 +/- 5 years). During the study period, patient freedom from late mortality was 61% (AVR, 61%; MVR, 63%), and from valve-related mortality 92% (AVR, 93%; MVR, 91%). Freedom from thromboembolic events was 85% (86% AVR, 81% MVR), from bleeding events, 81% (81% AVR, 81% MVR), from reoperation, 98% (99% AVR, 97% MVR), from endocarditis, 98% (99% AVR, 98% MVR), and from valve thrombosis, 99% (99% AVR, 98% MVR). There was one MVR structural failure (0.06%).

CONCLUSIONS

The St. Jude Medical valve has proven to be an effective and durable valve prosthesis with a low event rate during the long term.

Для цитирования: Emery Robert W, Krogh Christopher C, Arom Kit V, Emery Ann M, Benyo-Albrecht Kathy, Joyce Lyle D, Nicoloff Demetre M. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.. The Annals of thoracic surgery. 2005. DOI: 10.1016/j.athoracsur.2004.08.047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.