MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/eci.13385

Медицинская библиотека · European journal of clinical investigation · 2020

Compliance of atrial fibrillation treatment with the ABC pathway in patients with concomitant diabetes mellitus in the Middle East based on the Gulf SAFE registry.

Domek Magdalena, Gumprecht Jakub, Li Yan-Guang, Proietti Marco, Rashed Wafa, Al Qudaimi Ahmed, Gumprecht Janusz, Zubaid Mohammad, Lip Gregory Y H

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

Atrial fibrillation (AF) and diabetes mellitus (DM) constitute a heavy burden on healthcare expenditure due to their negative impact on clinical outcomes in the Middle East. The Atrial fibrillation Better Care (ABC) pathway provides a simple strategy of integrated approach of AF management: A-Avoid stroke; B-Better symptom control; C-Cardiovascular comorbidity risk management.

AIMS: Evaluation of the AF treatment compliance to ABC pathway in DM patients in the Middle East. Assessment of the impact of ABC pathway adherence on all-cause mortality and the composite outcome of stroke/systemic embolism, all-cause death and cardiovascular hospitalisations.

METHODS

From 2043 patients in the Gulf SAFE registry, 603 patients (mean age 63; 48% male) with DM were included in an analysis of ABC pathway compliance: A-appropriate use of anticoagulation according to CHA2 DS2 -VASc score; B-AF symptoms management according to the European Heart Rhythm Association (EHRA) scale; C-Optimised cardiovascular comorbidities management.

RESULTS

86 (14.3%) patients were treated in compliance with the ABC pathway. During 1-year follow-up, 207 composite outcome events and 87 deaths occurred. Mortality was significantly lower in the ABC group vs non-ABC (5.8% vs 15.9%, P = .0014, respectively). On multivariate analysis, ABC compliance was associated with a lower risk of all-cause death and the composite outcome after 6 months (OR 0.18; 95% CI: 0.42-0.75 and OR 0.54; 95% Cl: 0.30-1.00, respectively) and at 1 year (OR 0.30; 95% Cl: 0.11-0.76 and OR 0.57; 95% Cl: 0.33-0.97, respectively) vs the non-ABC group.

CONCLUSIONS

Compliance with the ABC pathway care was independently associated with the reduced risk of all-cause death and the composite outcome in DM patients with AF, highlighting the importance of an integrated approach to AF management.

Для цитирования: Domek Magdalena, Gumprecht Jakub, Li Yan-Guang, Proietti Marco, Rashed Wafa, Al Qudaimi Ahmed, Gumprecht Janusz, Zubaid Mohammad, Lip Gregory Y H. Compliance of atrial fibrillation treatment with the ABC pathway in patients with concomitant diabetes mellitus in the Middle East based on the Gulf SAFE registry.. European journal of clinical investigation. 2020. DOI: 10.1111/eci.13385.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.