MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.29150

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2020

Diagnostic accuracy of two-dimensional coronary angiographic-derived fractional flow reserve-Preliminary results.

Babakhani Hamid, Sadeghipour Parham, Tashakori Beheshti Ahmad, Ghasemi Massoud, Moosavi Jamal, Sadeghian Mohamad, Salesi Mahmood, Zahedmehr Ali, Shafe Omid, Shakerian Farshad, Mohebbi Bahram, Alemzadeh-Ansari Mohammad Javad, Firouzi Ata, Geraiely Babak, Abdi Seifollah

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

AIM: Noninvasive fractional flow reserve (NiFFR) is an emerging method for evaluating the functional significance of a coronary lesion during diagnostic coronary angiography (CAG). The method relies on the computational flow dynamics and the three-dimensional (3D) reconstruction of the vessel extracted from CAG. In the present study, we sought to evaluate the diagnostic performance and applicability of 2D-based NiFFR.

METHODS

In this prospective observational study, we evaluated 2D-based NiFFR in 279 candidates for invasive CAG and invasive fractional flow reserve (FFR). NiFFR was calculated via two methods: variable NiFFR, in which the contrast transport time was extracted from the angiographic view, and fixed NiFFR, in which a prespecified frame count was applied.

RESULTS

The final analysis was performed on 245 patients (250 lesions). Variable NiFFR had an area under the receiver operating characteristic curve of 81.5%, an accuracy of 80.0%, a sensitivity of 82.2%, a specificity of 82.2%, a negative predictive value of 91.4%, and a positive predictive value of 63.6%. The mean difference between FFR and NiFFR was -0.0244 ±.0616 (p ≤.0001). A pressure wire-free hybrid strategy was possible in 68.8% of our population with variable NiFFR.

CONCLUSIONS

Our 2D-based NiFFR yielded results comparable to those derived from 3D-based software. Our findings should; however, be confirmed in larger trials.

Для цитирования: Babakhani Hamid, Sadeghipour Parham, Tashakori Beheshti Ahmad, Ghasemi Massoud, Moosavi Jamal, Sadeghian Mohamad, Salesi Mahmood, Zahedmehr Ali, Shafe Omid, Shakerian Farshad, Mohebbi Bahram, Alemzadeh-Ansari Mohammad Javad, Firouzi Ata, Geraiely Babak, Abdi Seifollah. Diagnostic accuracy of two-dimensional coronary angiographic-derived fractional flow reserve-Preliminary results.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2020. DOI: 10.1002/ccd.29150.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.