MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bspc.2011.11.005

Медицинская библиотека · Biomedical signal processing and control · 2012

A study of non-invasive Patlak quantification for whole-body dynamic FDG-PET studies of mice.

Zheng Xiujuan, Wen Lingfeng, Yu Shu-Jung, Huang Sung-Cheng, Feng David Dagan

СтатьяПеревод пока не подготовлен

Аннотация

Physiological changes in dynamic PET images can be quantitatively estimated by kinetic modeling technique. The process of PET quantification usually requires an input function in the form of a plasma-time activity curve (PTAC), which is generally obtained by invasive arterial blood sampling. However, invasive arterial blood sampling poses many challenges especially for small animal studies, due to the subjects' limited blood volume and small blood vessels. A simple non-invasive quantification method based on Patlak graphical analysis (PGA) has been recently proposed to use a reference region to derive the relative influx rate for a target region without invasive blood sampling, and evaluated by using the simulation data of human brain FDG-PET studies. In this study, the non-invasive Patlak (nPGA) method was extended to whole-body dynamic small animal FDG-PET studies. The performance of nPGA was systematically investigated by using experimental mouse studies and computer simulations. The mouse studies showed high linearity of relative influx rates between the nPGA and PGA for most pairs of reference and target regions, when an appropriate underlying kinetic model was used. The simulation results demonstrated that the accuracy of the nPGA method was comparable to that of the PGA method, with a higher reliability for most pairs of reference and target regions. The results proved that the nPGA method could provide a non-invasive and indirect way for quantifying the FDG kinetics of tumor in small animal studies.

Для цитирования: Zheng Xiujuan, Wen Lingfeng, Yu Shu-Jung, Huang Sung-Cheng, Feng David Dagan. A study of non-invasive Patlak quantification for whole-body dynamic FDG-PET studies of mice.. Biomedical signal processing and control. 2012. DOI: 10.1016/j.bspc.2011.11.005.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.