MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.111.970285

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2012

Cardiac dysfunction and prolonged hemodynamic deterioration after implantable cardioverter-defibrillator shock in patients with systolic heart failure.

Toh Norihisa, Nishii Nobuhiro, Nakamura Kazufumi, Tada Takeshi, Oe Hiroki, Nagase Satoshi, Kohno Kunihisa, Morita Hiroshi, Kusano Kengo F, Ito Hiroshi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We investigated the acute effects of implantable cardioverter-defibrillator shock on myocardium, cardiac function, and hemodynamics in relation to left ventricular systolic function.

METHODS AND

RESULTS

We studied 50 patients who underwent implantable cardioverter-defibrillator implantation and defibrillation threshold (DFT) testing: 25 patients with left ventricular ejection fraction (LVEF) ≥ 45% and 25 patients with LVEF <45%. We measured cardiac biomarkers (creatine kinase, creatine kinase-MB, myoglobin, cardiac troponin T and I, and N-terminal probrain natriuretic peptide). Left ventricular relaxation was assessed by global longitudinal strain rate during the isovolumetric relaxation period using speckle-tracking echocardiography. Blood sampling and echocardiography were performed before, immediately after, and 5 minutes and 4 hours after DFT testing. Mean arterial pressure was measured directly during DFT testing. Cardiac biomarkers showed no significant changes in either group. LVEF was decreased until 5 minutes after DFT testing and had recovered to the baseline at 4 hours in the group with reduced LVEF (P<0.001), whereas LVEF reduction was not observed in the group with preserved LVEF (P=0.637). Global isovolumetric relaxation period was decreased until 5 minutes after DFT testing and had recovered to the baseline at 4 hours in both groups (preserved LVEF: 0.39 ± 0.14 versus 0.23 ± 0.13* versus 0.23 ± 0.13* versus 0.40 ± 0.13 s(-1), *P<0.001 versus baseline; reduced LVEF: 0.15 ± 0.05 versus 0.08 ± 0.04† versus 0.09 ± 0.04† versus 0.15 ± 0.05 s(-1), †P<0.001 versus baseline, repeated-measures ANOVA). Time to recovery of mean arterial pressure to the baseline was prolonged in the group with reduced LVEF (P<0.001).

CONCLUSIONS

Implantable cardioverter-defibrillator shock transiently impairs cardiac function and hemodynamics especially in patients with systolic dysfunction, although significant tissue injury is not observed.

Для цитирования: Toh Norihisa, Nishii Nobuhiro, Nakamura Kazufumi, Tada Takeshi, Oe Hiroki, Nagase Satoshi, Kohno Kunihisa, Morita Hiroshi, Kusano Kengo F, Ito Hiroshi. Cardiac dysfunction and prolonged hemodynamic deterioration after implantable cardioverter-defibrillator shock in patients with systolic heart failure.. Circulation. Arrhythmia and electrophysiology. 2012. DOI: 10.1161/circep.111.970285.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.