Improving dosing of gentamicin in the obese patient: a 3-cycle drug chart and case note audit.

Manjaly Joseph G, Reece-Smith Alexander M, Sivaloganathan Sivan S, Thuraisamy Christina, Smallwood Katie Lm, Jonas Elizabeth, Longman Robert J

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To assess the use of an electronic dose calculator to improve accuracy in the use of a complex Gentamicin prescription policy and assess turnaround time of blood sampling to dose delivery in an NHS hospital.

DESIGN

Retrospective review of drug chart, case notes and hospital antibiotic database.

SETTING

University Hospitals Bristol, UK

PARTICIPANTS

Patients receiving once daily intravenous gentamicin using the trust protocol, during the same time window for 3 consecutive years.

MAIN OUTCOME MEASURES: i) Accuracy of dose and frequency prescription of Gentamicin. ii) Time frame for measurement of serum Gentamicin levels.

RESULTS

Following the introduction of the online calculator, prescribing errors in obese patients dropped from 43% to 20%, a similar level as in non-obese patients. Errors in frequency calculations dropped from 12.8% to 4%. On average, drug doses could be administered within 2.5 hours of a blood sample being taken.

CONCLUSIONS

Online tools can be used to improve prescribing for the complex dosing policies that will increasingly been required to tailor prescribing in obese patients. Serum gentamicin levels can be measured within a 2.5 hour time frame in the environment of an NHS hospital.

Для цитирования: Manjaly Joseph G, Reece-Smith Alexander M, Sivaloganathan Sivan S, Thuraisamy Christina, Smallwood Katie Lm, Jonas Elizabeth, Longman Robert J. Improving dosing of gentamicin in the obese patient: a 3-cycle drug chart and case note audit.. JRSM short reports. 2012. DOI: 10.1258/shorts.2012.011131.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.