Efficacy of Alaska Pollock Gelatin Sealant for Pulmonary Air Leakage in Porcine Models.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yanagihara Takahiro, Maki Naoki, Wijesinghe A I, Sato Shoko, Saeki Yusuke, Kitazawa Shinsuke, Yamaoka Masatoshi, Kobayashi Naohiro, Kikuchi Shinji, Goto Yukinobu, Ichimura Hideo, Watanabe Shiharu, Taguchi Tetsushi, Sato Yukio
Аннотация
BACKGROUND: Postoperative prolonged air leakage is a frequent complication after lung resection. We have developed a new sealant based on a hydrophobically modified Alaska pollock-derived gelatin (ApGltn) sealant. The purpose of this study was to evaluate the adhesive strength of the ApGltn sealant in comparison with a fibrin sealant using a new spray system in ex vivo and in vivo models.
METHODS: Pleural defects in ex vivo and in vivo porcine models were created, to which the ApGltn sealant or the fibrin sealant was applied. The pressure resistance was assessed with a stepwise increase in airway pressure to confirm air leakage from the sealing site. Tissue samples covered with each sealant were obtained for histologic assessment.
RESULTS: In the ex vivo experiment, the leak pressures of the ApGltn sealant were significantly greater than those of the fibrin sealant (102.94 ± 15.6 cm H2O and 28.37 ± 5.1 cm H2O, respectively) (P < .01). In the in vivo experiment, the leak pressures of the ApGltn sealant were also significantly greater than those of the fibrin sealant (68.82 ± 18.04 cm H2O and 43.33 ± 7.13 cm H2O, respectively) (P = .043). The histologic examination confirmed that the ApGltn sealant adhered tightly to both the pleura and the surface of the pleural defect.
CONCLUSIONS: The ApGltn sealant has sufficiently high adhesive quality in ex vivo and in vivo porcine lungs, which could be considered suitable and effective for use in the prevention of air leakage from the lungs.
METHODS: Pleural defects in ex vivo and in vivo porcine models were created, to which the ApGltn sealant or the fibrin sealant was applied. The pressure resistance was assessed with a stepwise increase in airway pressure to confirm air leakage from the sealing site. Tissue samples covered with each sealant were obtained for histologic assessment.
RESULTS: In the ex vivo experiment, the leak pressures of the ApGltn sealant were significantly greater than those of the fibrin sealant (102.94 ± 15.6 cm H2O and 28.37 ± 5.1 cm H2O, respectively) (P < .01). In the in vivo experiment, the leak pressures of the ApGltn sealant were also significantly greater than those of the fibrin sealant (68.82 ± 18.04 cm H2O and 43.33 ± 7.13 cm H2O, respectively) (P = .043). The histologic examination confirmed that the ApGltn sealant adhered tightly to both the pleura and the surface of the pleural defect.
CONCLUSIONS: The ApGltn sealant has sufficiently high adhesive quality in ex vivo and in vivo porcine lungs, which could be considered suitable and effective for use in the prevention of air leakage from the lungs.