DOI 10.5694/j.1326-5377.1995.tb126027.x

Медицинская библиотека · The Medical journal of Australia · 1995

Infection associated with central venous catheters: a prospective survey.

Gosbell I B, Duggan D, Breust M, Mulholland K, Gottlieb T, Bradbury R

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the incidence of local and systemic infection caused by central venous catheters in a general hospital population.

SETTING

Concord Repatriation General Hospital, Sydney, April to August 1991 inclusive.

DESIGN

A prospective survey of all patients with in situ central venous catheters. Systemic catheter-related infection was detected by blood and routine catheter tip culture, and local infection by clinical observation of the catheter exit site.

OUTCOME MEASURES: Local and systemic infection and complications.

RESULTS

479 central venous catheters were surveyed in 311 patients. Local infection developed in association with 54 catheters (11%) and systemic infection with 32 (6.7%). Local infection was predictive of systemic infection, but its absence did not exclude systemic infection. Haemodialysis catheters were responsible for a higher systemic infection rate than other catheter types, the most common organism responsible being methicillin-resistant Staphylococcus aureus. Twenty per cent of all bacteraemias (33/160) detected in the hospital occurred in patients with a central venous catheter and 24 of these (73%) were definitely or probably due to the catheter. Staphylococci were the predominant isolates and 40% of the methicillin-resistant S. aureus bacteraemias detected were due to catheter-related infection. Infection complications were few: three patients developed local abscesses; one endocarditis; and two died.

CONCLUSIONS

Central venous catheter-related infection is common in general hospital populations. Staphylococcal bacteraemia and local infection in a patient with a central venous catheter are strongly suggestive of catheter-related systemic infection. Empirical antibiotic treatment should include at least antistaphylococcal cover.

Для цитирования: Gosbell I B, Duggan D, Breust M, Mulholland K, Gottlieb T, Bradbury R. Infection associated with central venous catheters: a prospective survey.. The Medical journal of Australia. 1995. DOI: 10.5694/j.1326-5377.1995.tb126027.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.