Gingival crevicular fluid biochemical markers in periodontal disease: a cross-sectional study.

Perozini Caroline, Chibebe Priscilla C A, Leao Mariella Vieira Pereira, Queiroz Celso da Silva, Pallos Debora

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the levels of interleukin-1b (IL-1b) and alkaline phosphatase (ALP) in gingival crevicular fluid (GCF) and correlate these measurements with clinical characteristics of healthy patients and patients with gingivitis and periodontitis.

METHOD AND MATERIALS: Thirty-six individuals were subdivided into three groups of 12: control, gingivitis, and periodontitis groups. GCF samples were obtained from 2 sites for each patient. GCF volume was measured with the Periotron 8000; IL-1b levels were evaluated using the ELISA technique; ALP was measured by the kinetic method.

RESULTS

Mean levels of IL-1b and ALP in the 3 groups were, respectively, 22.34 ± 16.53 ΜL/site and 7.68 ± 2.46 U/L in the control group; 41.46 ± 27.98 ΜL/site and 9.80 ± 1.53 U/L in the gingivitis group; and 105.97 ± 89.26 ΜL/site and 11.56 ± 1.82 U/L in the periodontitis group. The amount of IL-1b in the periodontitis group was significantly higher than in the other groups, but no significant difference was found between the control group and the gingivitis group. The amount of ALP differed significantly among the 3 groups (P < .05). A positive correlation was observed among IL-1b levels, GCF volume, and probing depth. There was no evidence for a correlation between IL-1b and ALP levels.

CONCLUSION

Monitoring immune markers may give additional information on healthy or diseased sites.

Для цитирования: Perozini Caroline, Chibebe Priscilla C A, Leao Mariella Vieira Pereira, Queiroz Celso da Silva, Pallos Debora. Gingival crevicular fluid biochemical markers in periodontal disease: a cross-sectional study.. Quintessence international (Berlin, Germany : 1985). 2010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.