OBJECTIVE

This study aimed to analyse the agreement in the clinical classification of keratoconus using four grading systems based exclusively on anterior corneal surface topographic parameters.

MATERIALS AND

METHODS

A retrospective, descriptive, analytical, cross-sectional study was conducted to evaluate agreement and differences among the keratometric scale, Amsler-Krumeich (A-K), Alió-Shabayek (A-S), and Keratoconus Severity Score (KSS) classifications. Retrospective, anonymised data were obtained from anterior corneal surface tomography, including keratometry, pachymetry, corneal aberrations, and the location of the thinnest corneal point, measured with a corneal tomographer (Pentacam®, Oculus Optikgeräte GmbH, Wetzlar, Germany). Agreement between each pair of ordinal scales was assessed using weighted Cohen's kappa coefficient with quadratic weights.

RESULTS

A total of 455 eyes with keratoconus were analysed. The mean age was 39.3 ± 12.2 years, with no significant sex differences (p > 0.05). Mean keratometry was 46.5 ± 5.9 D and mean pachymetry was 474.8 ± 70.2 μm. Only 111 eyes could be simultaneously classified across all four systems. Pairwise agreement analysis using weighted kappa revealed generally low concordance between classification systems. The highest agreement was observed between the keratometric and Amsler-Krumeich classifications (moderate agreement), whereas comparisons involving aberration-based systems showed weak to slight agreement. When classifications were based solely on each system's differential parameter, a similar pattern was observed, with moderate agreement between keratometric and pachymetry-based classifications and fair agreement in the remaining comparisons.

CONCLUSION

Keratoconus classification systems based on anterior corneal surface parameters show significant discrepancies and cannot be used interchangeably. Even when reduced to their primary defining parameters, agreement remains limited, indicating that these systems capture different dimensions of keratoconus severity.

Для цитирования: Villa-Collar Cesar, Santodomingo-Rubido Jacinto, Bodas-Romero Julia, Carracedo Gonzalo, Serramito María, Suzaki Asaki. Agreement in the classification of keratoconus severity: a comparative study based on anterior corneal surface topographic parameters.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2026. DOI: 10.1016/j.clae.2026.102696.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.