DOI 10.1177/0896860821993954

Медицинская библиотека · Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis · 2021

Clinical effectiveness of a Malaysian-manufactured CAPD product: A randomised trial.

Mak Wen Yao, Leong Chin Tho, Ong Loke Meng, Bavanandan Sunita, Mushahar Lily, Goh Bak Leong, Wong Hin Seng, Ahmad Ghazali, Liew Yew Fong, Ching Chen Hua, Liu Wen Jiun, Rahmat Korina, Tan Clare Hui-Hong, Ahmad Mohd Kamil, Hassan Wan Hasnul Halimi Wan, Chan Fei Sia, Harun Zaiha, Loh Chek Loong, Teng Kok Seng, Tye Yi Loon, Khan Shahnaz Shah Firdaus, Koh Keng-Hee, Abdullah Rafidah, Hooi Lai Seong

СтатьяМногоцентровое исследованиеРандомизированное исследованиеEquivalence TrialПеревод пока не подготовлен

Аннотация

BACKGROUND

We compared the clinical effectiveness of a new peritoneal dialysis (PD) product with polyvinyl chloride-containing tubing (Stay Safe Link®, SSL) with the plastic-free alternative (Stay Safe®, STS) in patients on continuous ambulatory peritoneal dialysis (CAPD).

METHOD: A multicentre, parallel, randomised, controlled, open-label, non-inferiority trial was conducted. Adult patients receiving CAPD were randomised in a 1:1 ratio to SSL or STS. The primary outcome was the rate of peritonitis after 1 year of follow-up.

RESULTS

A total of 472 subjects were randomised (SSL, n = 233; STS, n = 239). One subject in each group was excluded from the analysis as they withdrew consent before the first dialysis dose. Four hundred and seventy subjects (SSL, n = 232; STS, n = 238) were included in the modified intention-to-treat analysis. Non-inferiority between two groups was established as no significant difference was found in peritonitis rate (incident rate ratio: 0.91, 95% CI: 0.65-1.28). No significant difference was detected in weekly Kt/V (p = 0.58) and creatinine clearance (p = 0.55). However, the average ultrafiltration volume was significantly lower in SSL, with a mean difference of 93 ml (p < 0.01). SSL also demonstrated a 2.57-times higher risk of device defect than STS (95% CI: 1.77-3.75).

CONCLUSION

SSL was non-inferior in peritonitis rate compared to plastic-free STS over 1 year in patients requiring CAPD. There was no difference in the delivered dialysis dose, but there was a higher rate of device defects with SSL.

Для цитирования: Mak Wen Yao, Leong Chin Tho, Ong Loke Meng, Bavanandan Sunita, Mushahar Lily, Goh Bak Leong, Wong Hin Seng, Ahmad Ghazali, Liew Yew Fong, Ching Chen Hua, Liu Wen Jiun, Rahmat Korina, Tan Clare Hui-Hong, Ahmad Mohd Kamil, Hassan Wan Hasnul Halimi Wan, Chan Fei Sia, Harun Zaiha, Loh Chek Loong, Teng Kok Seng, Tye Yi Loon, Khan Shahnaz Shah Firdaus, Koh Keng-Hee, Abdullah Rafidah, Hooi Lai Seong. Clinical effectiveness of a Malaysian-manufactured CAPD product: A randomised trial.. Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis. 2021. DOI: 10.1177/0896860821993954.