Acta orthopaedica · 2013
Trabecular metal tibia still stable at 5 years: an RSA study of 36 patients aged less than 60 years.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Henricson Anders, Rösmark Dan, Nilsson Kjell G
Аннотация
BACKGROUND AND PURPOSE: Clinical results of total knee replacement (TKR) are inferior in younger patients, mainly due to aseptic loosening. Coating of components with trabecular metal (TM) is a new way of enhancing fixation to bone. We have previously reported stabilization of TM tibial components at 2 years. We now report the 5-year follow-up of these patients, including RSA of their TM tibial components.
PATIENTS AND METHODS: 22 patients (26 knees) received an uncemented TM cruciate-retaining tibial component and 19 patients (21 knees) a cemented NexGen Option cruciate-retaining tibial component. Follow-up with RSA, and clinical and radiographic examinations were done at 5 years. In bilaterally operated patients, the statistical analyses included only the first-operated knee.
RESULTS: Both groups had most migration within the first 3 months, the TM implants to a greater extent than the cemented implants. After 3 months, both groups stabilized and remained stable up to the 5-year follow-up.
INTERPRETATION: After a high initial degree of migration, the TM tibia stabilized. This stabilization lasted for at least 5 years, which suggests a good long-term performance regarding fixation. The cemented NexGen CR tibial components showed some migration in the first 3 months and then stabilized up to the 5-year follow-up. This has not been reported previously.
PATIENTS AND METHODS: 22 patients (26 knees) received an uncemented TM cruciate-retaining tibial component and 19 patients (21 knees) a cemented NexGen Option cruciate-retaining tibial component. Follow-up with RSA, and clinical and radiographic examinations were done at 5 years. In bilaterally operated patients, the statistical analyses included only the first-operated knee.
RESULTS: Both groups had most migration within the first 3 months, the TM implants to a greater extent than the cemented implants. After 3 months, both groups stabilized and remained stable up to the 5-year follow-up.
INTERPRETATION: After a high initial degree of migration, the TM tibia stabilized. This stabilization lasted for at least 5 years, which suggests a good long-term performance regarding fixation. The cemented NexGen CR tibial components showed some migration in the first 3 months and then stabilized up to the 5-year follow-up. This has not been reported previously.