MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/clr.12213

Медицинская библиотека · Clinical oral implants research · 2013

Nanostructures and hydrophilicity influence osseointegration: a biomechanical study in the rabbit tibia.

Wennerberg Ann, Jimbo Ryo, Stübinger Stefan, Obrecht Marcel, Dard Michel, Berner Simon

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Implant surface properties have long been identified as an important factor to promote osseointegration. The importance of nanostructures and hydrophilicity has recently been discussed. The aim of this study was to investigate how nanostructures and wettability influence osseointegration and to identify whether the wettability, the nanostructure or both in combination play the key role in improved osseointegration.

MATERIALS AND

METHODS

Twenty-six adult rabbits each received two Ti grade 4 discs in each tibia. Four different types of surface modifications with different wettability and nanostructures were prepared: hydrophobic without nanostructures (SLA), with nanostructures (SLAnano); hydrophilic with two different nanostructure densities (low density: pmodSLA, high density: SLActive). All four groups were intended to have similar chemistry and microroughness. The surfaces were evaluated with contact angle measurements, X-ray photoelectron spectroscopy, scanning electron microscopy, atomic force microscopy and interferometry. After 4 and 8 weeks healing time, pull-out tests were performed.

RESULTS

SLA and SLAnano were hydrophobic, whereas SLActive and pmodSLA were super-hydrophilic. No nanostructures were present on the SLA surface, but the three other surface modifications clearly showed the presence of nanostructures, although more sparsely distributed on pmodSLA. The hydrophobic samples showed higher carbon contamination levels compared with the hydrophilic samples. After 4 weeks healing time, SLActive implants showed the highest pull-out values, with significantly higher pull-out force than SLA and SLAnano. After 8 weeks, the SLActive implants had the highest pull-out force, significantly higher than SLAnano and SLA.

CONCLUSIONS

The strongest bone response was achieved with a combination of wettability and the presence of nanostructures (SLActive).

Для цитирования: Wennerberg Ann, Jimbo Ryo, Stübinger Stefan, Obrecht Marcel, Dard Michel, Berner Simon. Nanostructures and hydrophilicity influence osseointegration: a biomechanical study in the rabbit tibia.. Clinical oral implants research. 2013. DOI: 10.1111/clr.12213.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.