Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis.

Weber Patrick, Crispin Alexander, Schmidutz Florian, Utzschneider Sandra, Pietschmann Matthias F, Jansson Volkmar, Müller Peter E

СтатьяМетаанализПеревод пока не подготовлен

Аннотация

PURPOSE: Inaccurate implantation rates of up to 30 % have been reported in cases using the conventional technique for implantation of a unicompartmental knee arthroplasty. Navigation should permit a more precise implantation, and several studies have investigated its role, albeit with a limited number of patients and inconsistent results. The aim of this meta-analysis was to compare risks of unsatisfactory outcomes in patients with navigated and conventional technique.

METHODS

An electronic search was performed, and ten studies were eligible and included in the meta-analysis, with a total of 258 prostheses implanted with the navigated technique and 295 with the conventional one. The following items were analysed: radiological positioning of the femoral and the tibial component in the AP and lateral view, radiological analysis of the tibiofemoral mechanical axis and the difference in operating time between the two groups. Relative risks (RR) were calculated from the reported percentages of implants outside the optimal ranges defined by the manufacturers or the study groups. Natural logarithms of the relative risks were pooled by means of random effects models.

RESULTS

For all the analysed radiological parameters, the RR of measurements outside the optimal ranges were less than 1 in the navigation group suggesting a reduction in the risk of outliers with navigation. The average operating time in the navigated group was 15.4 min (95 % CI: 10.2-20.6) longer than in the conventional group.

CONCLUSION

The meta-analysis shows that the use of navigation systems in UKA leads to a more precise component position. Whether the more accurate position in UKA results in a better clinical outcome or long-term survival is yet unknown. Nevertheless, as a precise implant position appears to be beneficial, the use of navigation should be recommended for UKA. The limits defined by the manufacturers for an optimal positioning are not consistent.

Для цитирования: Weber Patrick, Crispin Alexander, Schmidutz Florian, Utzschneider Sandra, Pietschmann Matthias F, Jansson Volkmar, Müller Peter E. Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2013. DOI: 10.1007/s00167-013-2370-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.