MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2024.02.010

Медицинская библиотека · Journal of the American College of Cardiology · 2024

Early Outcomes From a Multicenter Transcatheter Self-Expanding Pulmonary Valve Replacement Registry.

Goldstein Bryan H, McElhinney Doff B, Gillespie Matthew J, Aboulhosn Jamil A, Levi Daniel S, Morray Brian H, Cabalka Allison K, Love Barry A, Zampi Jeffrey D, Balzer David T, Law Mark A, Schiff Mary D, Hoskoppal Arvind, Qureshi Athar M

Многоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021.

OBJECTIVES

In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience.

METHODS

This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S.

CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention.

RESULTS

A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2).

CONCLUSIONS

In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.

Для цитирования: Goldstein Bryan H, McElhinney Doff B, Gillespie Matthew J, Aboulhosn Jamil A, Levi Daniel S, Morray Brian H, Cabalka Allison K, Love Barry A, Zampi Jeffrey D, Balzer David T, Law Mark A, Schiff Mary D, Hoskoppal Arvind, Qureshi Athar M. Early Outcomes From a Multicenter Transcatheter Self-Expanding Pulmonary Valve Replacement Registry.. Journal of the American College of Cardiology. 2024. DOI: 10.1016/j.jacc.2024.02.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.