m+Medelevator.RU
← Поиск публикаций
International archives of otorhinolaryngology · 2025

Bilateral Fitting of Bone-Anchored Hearing Devices: Speech Recognition and Sound Localization.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ueda Cynthia Harumi Yokoyama, Jardim Isabela de Souza, Bento Ricardo Ferreira, Soares Renata Marcial

Аннотация

INTRODUCTION: Bilateral fitting of bone-anchored hearing devices (BAHD) remains a contentious topic, as the use of a single device can direct sound to both cochleae. However, the interplay of interaural attenuation and time delay may result in different responses in each ear; thus, greater challenges for unilateral BAHD users.

OBJECTIVE: To assess the auditory performance of BAHD users with unilateral and bilateral fitting regarding speech recognition in silence and noise and sound localization.

METHODS: Cross-sectional study. Unilateral BAHD users treated at a Brazilian public hospital underwent a speech recognition test, containing a list of monosyllables at 65dBSPL in silence and noise (S/N ratio = 0dB). The sound localization test employed eight speakers arranged at 45° distance. A recorded trisyllabic word served as the stimulus. For bilateral fitting, an elastic band with a device similar to the implant was used; patients underwent the same tests under identical conditions.

RESULTS: Sixteen patients were assessed (mean age = 24.2 years). The average monosyllable recognition in silence rate was 71.5% in unilateral fitting and 78.2% in bilateral fitting. In noise, 61% in unilateral fitting and 72.2% in bilateral fitting. The mean angular deviation for the sound localization test was 80.48° in unilateral fitting and 68.08° in bilateral fitting. The bilateral fitting outcomes were better for all tests.

CONCLUSION: Users with bilateral BAHD fitting had better outcomes for speech recognition and sound localization.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты