A Clinical and Radiographic 3 Years Retrospective Study for Two Types of Locator Retained Mandibular Implant Overdenture.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ibrahim Christine Raouf Micheal, Ahmed Aboelez Marwa, Elkashty Ayman Abdel Rahim Mohammed, Awad Heba Nabil

Аннотация

INTRODUCTION: This retrospective study aimed to evaluate peri-implant marginal bone loss (MBL) and prosthetic complications between two types of locator attachments in two implant-supported mandibular overdentures.

MATERIAL AND METHOD: From the archived records, information about patients who had two implants inserted utilizing two different types of locator attachments into the interforaminal region between November 2019 and December 2023 was obtained. Overall, 60 patients (Total = 120 implants) from the archive records of the Prosthodontics Department, Faculty of Dentistry, Mansoura University, with ages ranging from 40 to 60 (mean age 50), were included in the study. Group I (control): Overall, 30 patients who would be delivered mandibular implant overdenture using conventional locator attachments. Group II (study): Overall, 30 patients who would be delivered mandibular implant overdenture using RTx locator attachments. After the placement of the mandibular overdenture (T0), 6 months (T6), 12 months (T12), and 3 years (T3) later, the marginal bone loss (MBL) was assessed. Prosthetic complications were evaluated for both groups 3 years after prosthetic delivery.

RESULT: A statistically significant increase (p = 0.000) was found in MBL scores at all observation times between both groups. Group II showed a statistical increase in MBL than Group I. For prosthetic complications, no significant difference was found between both groups. Group II showed more matrix wear than Group I however, it was not statistically significant (p = 0.60).

CONCLUSION: Within the limitation of this study, we can conclude the following: Both types of locator attachment (conventional and RTx locator) can be used clinically with no preference concerning the frequency of prosthetic complications. From the MBL perspective, conventional locators are more favorable than RTx locators.