MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2011.06.031

Медицинская библиотека · American journal of ophthalmology · 2012

Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy.

Kojima Takashi, Yokoyama Sho, Ito Mayuka, Horai Rie, Hara Shuya, Nakamura Tomoaki, Ichikawa Kazuo

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To develop and evaluate a new implantable collamer lens (ICL) sizing method that uses high-frequency ultrasound biomicroscopy (UBM).

DESIGN

Interventional case series.

METHODS

ICL were implanted in 47 eyes of 25 patients (8 male, 17 female, mean age 34.7±6.8 years). At 3 months after ICL surgery, the vault (distance between ICL and crystalline lens) was measured using anterior optical coherence tomography (OCT). Stepwise multiple regression analysis was performed in order to determine the optimal ICL size that will be expected to achieve a 0.5-mm vault, and the regression equation was calculated. Mean keratometric power, axial length, anterior chamber depth, sulcus-to-sulcus (STS) diameter, and distance between STS plane and crystalline lens were applied as candidates for explanatory variables. Subsequently, the equation was applied to a new group of patients (81 eyes of 43 patients, 20 male and 23 female, mean age 35.6±7.2 years) in order to decide the ICL size. Postoperative vault was evaluated at 3 months after surgery. Main outcome measures were mean postoperative vault and percentages of eyes that achieved moderate vault.

RESULTS

The regression equation was determined using 3 explanatory variables: anterior chamber depth (ACD), STS diameter, and distance between STS plane and anterior crystalline lens surface (STSL). The mean vault error (postoperative vault-predicted vault) was -0.06±0.29 mm. Of the total number of eyes, 88.9% had a vault between 0.15 and 1.0 mm. None of the eyes had a low vault (<0.15 mm). Nine eyes (11.1%) had a high vault (>1.0 mm).

CONCLUSION

A novel ICL sizing equation was developed and shown to be an effective method for calculation of the optimal ICL size in order to achieve an appropriate vault.

Для цитирования: Kojima Takashi, Yokoyama Sho, Ito Mayuka, Horai Rie, Hara Shuya, Nakamura Tomoaki, Ichikawa Kazuo. Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy.. American journal of ophthalmology. 2012. DOI: 10.1016/j.ajo.2011.06.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.