MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-019-56972-0

Медицинская библиотека · Scientific reports · 2020

Concordance of copy number abnormality detection using SNP arrays and Multiplex Ligation-dependent Probe Amplification (MLPA) in acute lymphoblastic leukaemia.

Bashton Matthew, Hollis Robin, Ryan Sarra, Schwab Claire J, Moppett John, Harrison Christine J, Moorman Anthony V, Enshaei Amir

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

In acute lymphoblastic leukaemia, MLPA has been used in research studies to identify clinically relevant copy number abnormality (CNA) profiles. However, in diagnostic settings other techniques are often employed. We assess whether equivalent CNA profiles are called using SNP arrays, ensuring platform independence. We demonstrate concordance between SNP6.0 and MLPA CNA calling on 143 leukaemia samples from two UK trials; comparing 1,287 calls within eight genes and a region. The techniques are 99% concordant using manually augmented calling, and 98% concordant using an automated pipeline. We classify these discordant calls and examine reasons for discordance. In nine cases the circular binary segmentation (CBS) algorithm failed to detect focal abnormalities or those flanking gaps in IKZF1 probe coverage. Eight cases were discordant due to probe design differences, with focal abnormalities detectable using one technique not observable by the other. Risk classification using manually augmented array calling resulted in four out of 143 patients being assigned to a different CNA risk group and eight patients using the automated pipeline. We conclude that MLPA defined CNA profiles can be accurately mirrored by SNP6.0 or similar array platforms. Automated calling using the CBS algorithm proved successful, except for IKZF1 which should be manually inspected.

Для цитирования: Bashton Matthew, Hollis Robin, Ryan Sarra, Schwab Claire J, Moppett John, Harrison Christine J, Moorman Anthony V, Enshaei Amir. Concordance of copy number abnormality detection using SNP arrays and Multiplex Ligation-dependent Probe Amplification (MLPA) in acute lymphoblastic leukaemia.. Scientific reports. 2020. DOI: 10.1038/s41598-019-56972-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.