MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2006.08.009

Медицинская библиотека · European journal of radiology · 2006

Bowel preparation for CT-colonography: comparison of two different cleansing protocols.

Juchems Markus S, Hoffmann Martin H K, Schmidt Stefan A, Apostel Anna, Brambs Hans-Juergen, Aschoff Andrik J

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Comparison of cleansing effects and colonic distension observed with two polyethyleneglycol-solution (PEG) containing bowel preparation techniques prior to CT-colonography (CTC).

MATERIALS AND

METHODS

One hundred and three patients that received CTC in our institution were retrospectively evaluated. Fifty-one patients received preparation 1 (BP1; based on a GoLytely formulation+bisacodyl), 52 preparation 2 (BP2; based on a NuLytely formulation+bisacodyl). On multi-planar-reformatted (MPR) images, fluid residuals and colon distension were assessed in five colonic segments, from the ascending colon to the rectum.

RESULTS

On average, significantly (p<0.001) lower fluid residuals were assesses when using BP2 regardless of the patient position. In prone position, a significantly lower fluid level was observed in the sigmoid using bowel preparation 2. The average maximum diameter measured for the whole colon was 5.2+/-0.6 cm in prone position and 4.8+/-0.6 cm in the supine position in BP1 (p<0.01). In BP2 the average maximum diameter measured for the whole colon was 5.3+/-0.6 cm in prone position and 4.7+/-0.5 cm in supine position, respectively (p<0.001).

CONCLUSION

Overall, lower fluid residuals were scored using BP2. In both preparation groups we achieved better colonic distension in prone position. We were not able to distend the sigmoid better when insufflating air during patient repositioning.

Для цитирования: Juchems Markus S, Hoffmann Martin H K, Schmidt Stefan A, Apostel Anna, Brambs Hans-Juergen, Aschoff Andrik J. Bowel preparation for CT-colonography: comparison of two different cleansing protocols.. European journal of radiology. 2006. DOI: 10.1016/j.ejrad.2006.08.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.