BACKGROUND

An intravaginal device (IVD) made from polyethylene plastic and copper wire, integrated with a radio frequency identification (RFID) chip, was developed as a biocompatible contraceptive and identity device for cats.

AIM: This study evaluates the local and systemic biocompatibility of IVD in five non-pregnant female cats.

METHODS

The IVD was successfully inserted into the vaginal lumen after estrogen administration. Radiographic imaging confirmed the IVD's position, which lasted up to two days post-insertion.

RESULTS

Systemic response, assessed through hematological examinations on days 0, 1, and 3 post-insertion, showed no significant changes in erythrogram and leukogram parameters. Local response, evaluated through vulvar inspection and vaginal cytology on days 0, 1, 3, and 7, revealed no neutrophil infiltration in 4 out of 5 cats, indicating compatibility with vaginal tissue. Furthermore, epithelial cell profile changes were observed, showing an increase in superficial cells, which is typical during the estrus phase.

CONCLUSION

These findings suggest that the IVD is biocompatible and suitable for use as a contraceptive and identity device in cats. However, further long-term studies are necessary to evaluate the device's prolonged efficacy and potential for contraception failure prevention by mating trials.

Для цитирования: Santoso Muhammad Irham Bagus, Ainun Sella Sofia, Utami Dian, Aziz Fathan Abdul, Puspitaningsih Resti, Ashar Yaomil, Gunanti Gunanti, Sarian Murni Nazira, Ulum Mokhammad Fakhrul. Biocompatibility assessment of an integrated contraceptive and RFID-based intravaginal device in cats (Felis catus): A preliminary study.. Open veterinary journal. 2024. DOI: 10.5455/ovj.2024.v14.i9.23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.