DOI 10.1016/j.otohns.2005.07.027
Long-term results of palatal implants for primary snoring.
Аннотация
OBJECTIVE
To determine the safety and efficacy of the Pillar Palatal Implant System over a 1-year follow-up period.
STUDY DESIGN AND
SETTING
In this prospective study, 40 healthy adult patients with primary snoring due to palatal flutter were treated after clinical, polysomnographic, and endoscopic examination. Under local anesthesia 3 implants were placed into the soft palate. Postoperative morbidity and functional parameters were assessed. Snoring and daytime sleepiness were assessed before and 90, 180, and 360 days after surgery. Objective data were obtained by polysomnography and SNAP-recording before and 90 days after treatment.
RESULTS
All implants were placed without complications. A total of 13 implants partially extruded uneventfully in 10 patients. Functional parameters remained unchanged. After 1 year, snoring was reduced from 7.1 +/- 1.9 to 4.8 +/- 2.5 (Visual-Analogue-Scale, P < 0.05) and daytime sleepiness from 6.1 +/- 3.2 to 4.9 +/- 3.1 (Epworth-Sleepiness-Scale, P < 0.05). SNAP data and polysomnography parameters showed clinically irrelevant changes.
CONCLUSION
Our data demonstrate a significant decrease in snoring and daytime sleepiness over a period of one year.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.