Feasibility of using an led-probe in third-space endoscopy: a clinical study.
Аннотация
BACKGROUND
Third-space endoscopy is a novel, safe, and effective method for treating different gastrointestinal conditions. However, several failed endoscopic procedures are attributed to incomplete myotomy. Lighting devices are used to prevent organic injuries. We aimed to investigate the feasibility of using a hand-made LED-probe (LP) in third-space procedures.
METHODS
This prospective study was conducted in a tertiary-care center in Mexico between December 2016 and January 2019. We included peroral endoscopic myotomy (POEM) and gastric peroral endoscopic myotomy(G-POEM) procedures. Pseudoachalasia, peptic ulcer, normal gastric emptying scintigraphy (GES) and prepyloric tumors were excluded. LP was used to guide or confirm procedures. Clinical and procedural characteristics were recorded and analyzed.
RESULTS
Seventy third-space procedures were included (42POEM,28G-POEM), with an average patient age of 46.7 ± 14.3 and 43.7 ± 10.1 years, respectively. For the POEM and G-POEM groups, respectively, 18/42(42.9%) and 13/28(46.7%) patients were males; median procedure times were 50 (interquartile range [IQR]: 38-71) and 60(IQR: 48-77) min, median LP placement times were 5(IQR: 4-6) and 6(IQR: 5-7) min, mild adverse events occurred in 4(9.4%) and 4(14.2%) of cases, and clinical success at 6 months occurred in 100 and 85.7% of cases. Integrated relaxation pressure (IRP) improved from 27.3 ± 10.8 to 9.5 ± 4.1 mmHg (p < 0.001); retention percentage at 4 h also improved. LP was successfully placed and adequate myotomy confirmed including 14.2 and 17.8% of POEM and G-POEM difficult patients.
CONCLUSIONS
Using an LP is promising and allows guiding during third-space procedures either for submucosal tunnel creation or myotomy confirmation, with excellent safety and efficacy in clinical practice.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.