MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/nmo.13847

Медицинская библиотека · Neurogastroenterology and motility · 2020

New parameter for quantifying bolus transit with high-resolution impedance manometry: A comparison with simultaneous esophagogram.

Gong Eun Jeong, Choi Kyungmin, Jung Kee Wook, Pandolfino John E, Kim Do Yeon, Yoon In Ja, Seo So Young, Koo Hyun Sook, Na Hee Kyong, Ahn Ji Yong, Lee Jeong Hoon, Choi Kee Don, Kim Do Hoon, Song Ho June, Lee Gin Hyug, Jung Hwoon-Yong, Myung Seung-Jae, Kim Nayoung, Joo Segyeong

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Esophageal bolus transit can be assessed using esophagogram or high-resolution impedance manometry (HRIM). The three-dimensional volume of inverted impedance (VII) has been developed to quantify the residual bolus between each swallow through spatiotemporal analysis. However, this novel metric has not been validated against simultaneous esophagogram.

METHODS

A total of nine healthy volunteers (Seven males, aged 19-45 years) were prospectively evaluated with HRIM and barium esophagogram. In addition, 21 symptomatic patients (12 males, aged 20-85 years) without major motility disorder were also included. The VII was estimated from HRIM data using MATLAB program and was compared with residual bolus volume in the esophagus estimated from simultaneous esophagogram.

KEY

RESULTS

A total of 80 swallows (24 in controls and 56 in patients) were analyzed. Results from the VII method were concordant with the bolus transit pattern estimated from the esophagogram in 91.3% (73/80) of swallows. The correlation between quantitative data from VII and the volume of residual bolus estimated from esophagogram was strong in both groups with a Pearson's correlation coefficient of 0.805 for healthy volunteers and 0.730 for symptomatic patients. The intraclass correlation coefficient of VII between the three swallows within a subject was 0.901 in healthy subjects and 0.705 in patients, indicating a modest reliability of this method.

CONCLUSIONS AND INFERENCES: The newly developed VII method is a reliable method in assessing residual bolus volume in the esophagus based on comparison with bolus volume estimated from simultaneous esophagogram.

Для цитирования: Gong Eun Jeong, Choi Kyungmin, Jung Kee Wook, Pandolfino John E, Kim Do Yeon, Yoon In Ja, Seo So Young, Koo Hyun Sook, Na Hee Kyong, Ahn Ji Yong, Lee Jeong Hoon, Choi Kee Don, Kim Do Hoon, Song Ho June, Lee Gin Hyug, Jung Hwoon-Yong, Myung Seung-Jae, Kim Nayoung, Joo Segyeong. New parameter for quantifying bolus transit with high-resolution impedance manometry: A comparison with simultaneous esophagogram.. Neurogastroenterology and motility. 2020. DOI: 10.1111/nmo.13847.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.