High-Dose-Rate (192)Ir Brachytherapy Dose Verification: A Phantom Study.

Nikoofar Alireza, Hoseinpour Zohreh, Rabi Mahdavi Seied, Hasanzadeh Hadi, Rezaei Tavirani Mostafa

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The high-dose-rate (HDR) brachytherapy might be an effective tool for palliation of dysphagia. Because of some concerns about adverse effects due to absorbed radiation dose, it is important to estimate absorbed dose in risky organs during this treatment.

OBJECTIVES

This study aimed to measure the absorbed dose in the parotid, thyroid, and submandibular gland, eye, trachea, spinal cord, and manubrium of sternum in brachytherapy in an anthropomorphic phantom.

MATERIALS AND

METHODS

To measure radiation dose, eye, parotid, thyroid, and submandibular gland, spine, and sternum, an anthropomorphic phantom was considered with applicators to set thermoluminescence dosimeters (TLDs). A specific target volume of about 23 cm(3) in the upper thoracic esophagus was considered as target, and phantom planned computed tomography (CT) for HDR brachytherapy, then with a micro-Selectron HDR ((192)Ir) remote after-loading unit.

RESULTS

Absorbed doses were measured with calibrated TLDs and were expressed in centi-Gray (cGy). In regions far from target (≥ 16 cm) such as submandibular, parotid and thyroid glands, mean measured dose ranged from 1.65 to 5.5 cGy. In closer regions (≤ 16 cm), the absorbed dose might be as high as 113 cGy.

CONCLUSIONS

Our study showed similar depth and surface doses; in closer regions, the surface and depth doses differed significantly due to the role of primary radiation that had imposed a high-dose gradient and difference between the plan and measurement, which was more severe because of simplifications in tissue inhomogeneity, considered in TPS relative to phantom.

Для цитирования: Nikoofar Alireza, Hoseinpour Zohreh, Rabi Mahdavi Seied, Hasanzadeh Hadi, Rezaei Tavirani Mostafa. High-Dose-Rate (192)Ir Brachytherapy Dose Verification: A Phantom Study.. Iranian journal of cancer prevention. 2015. DOI: 10.17795/ijcp2330.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.