m+Medelevator.RU
← Поиск публикаций
Transfusion · 2025

Use of research-grade radioisotopes for in-human recovery and survival studies.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Brown Bethany L, Wellington Michael, Cleeton Stephanie, Brown Alexus, Zittermann Sandra, Calderone Zohreh Tatari, Whitley Pamela

Аннотация

BACKGROUND AND OBJECTIVES: Red blood cells (RBCs) and platelets are evaluated for in vivo quality using recovery and survival measurements in healthy volunteers. Radiolabeling is the standard method for tracking blood cells post-transfusion. The supply of chromium-51 (51Cr) manufactured under Good Manufacturing Practices (GMP) has been challenging, and in 2024, the only remaining supplier ceased production. Now, only research-grade 51Cr is available, requiring risk control measures. Simultaneously, the Pyrophosphate (PYP) kits used to condition RBCs for technetium-99m (99mTc) labeling are also no longer available. This report summarizes validations performed leading to reinfusions of blood cells labeled with a new kit for 99mTc RBC labeling and research-grade 51Cr.

MATERIALS AND METHODS: Three validations were conducted to confirm: (1) labeling efficiency of an alternative kit for 99mTc labeling RBCs, (2) safety and labeling efficiency using research-grade 51Cr, and (3) the ability of the Pyrosate®-Rapid Endotoxin Detection (PRED) kit to detect pyrogens in research-grade material and in end-products for in vivo use.

RESULTS: Labeling efficiency of RBCs with 99mTc using the Ultratag™ RBC kit was >98% and demonstrated consistency in labeling across different sample preparation conditions. Filtration of the radioisotope stock and endotoxin testing of the infusate served as effective risk mitigation steps, supporting safe use of research-grade 51Cr, with labeling efficiency >98%.

CONCLUSIONS: We validated the use of research-grade 51Cr, an updated kit for 99mTc labeling, and endotoxin testing for in vivo reinfusion of research-grade 51Cr labeled blood cells, and have infused >30 research participants with these changes under US FDA-approved protocols.