MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/15459624.2025.2563550

Медицинская библиотека · Journal of occupational and environmental hygiene · 2025

A novel approach for evaluating the containment of a closed intravenous administration system for hazardous drugs.

Slutsky Smith Elana A, Alon Asaf

СтатьяПеревод пока не подготовлен

Аннотация

Oncology nurses are routinely exposed to antineoplastic agents through skin absorption or inhalation of airborne agents when administering drugs intravenously. Although safe infusion devices aimed at preventing the hazardous disconnection of empty bags were developed, none of them are completely closed systems per National Institute for Occupational Safety and Health (NIOSH) guidelines. The authors evaluated a closed system administration device developed to prevent exposure of healthcare professionals to cytotoxic drugs during their administration. System components were assembled in various scenarios mimicking intravenous drug administration and then tested in a sealed chamber connected to a gas analyzer. The concentration of 70% isopropanol vapors (as a drug surrogate) was measured continuously in the chamber. The analysis showed no detectable increase in isopropanol vapor concentration in the sealed chamber compared to baseline levels over the course of the tasks, indicating that no leaks of 70% isopropanol occurred when the closed system administration devices were used. Furthermore, the results remained the same regardless of the number of connection cycles the products had undergone, or whether they were newly manufactured or at the simulated end of their shelf-life. This study showed that the use of a closed administration system can minimize the risk of exposure of healthcare professionals to hazardous drugs and potentially reduce environmental contamination.

Для цитирования: Slutsky Smith Elana A, Alon Asaf. A novel approach for evaluating the containment of a closed intravenous administration system for hazardous drugs.. Journal of occupational and environmental hygiene. 2025. DOI: 10.1080/15459624.2025.2563550.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.