Efficacy and safety of progressive fluence pulsed light epithelium-on accelerated corneal cross-linking for progressive keratoconus: 18-month prospective results.

Ferrise Marco, Gagliano Caterina, D'Esposito Fabiana, Cappellani Francesco, Zagari Marco, Mazzotta Cosimo

СтатьяПеревод в очереди

Аннотация

AIM: To report the 18-month clinical outcomes of the progressively higher fluence pulsed light (7.2 to 10 J/cm2) epithelium-on accelerated corneal crosslinking (PFPL M Epi-On ACXL) protocol for progressive keratoconus.

METHODS

This was a prospective, non-randomized interventional study. Fluence was assigned based on preoperative pachymetry: 7.2 J/cm2 (≤420 µm), 8.6 J/cm2 (420-459 µm), or 10 J/cm2 (≥460 µm). Riboflavin solutions (Paracel I and II), pulsed ultraviolet-A (UVA) irradiation (1s on/off), and consistent procedural timing (13min irradiation) were applied using the KXL I system. Uncorrected and best-corrected distance visual acuity (UDVA, CDVA), maximum keratometry (Kmax), higher-order aberrations (HOAs), and anterior segment optical coherence tomography (OCT) demarcation line depth were analyzed at baseline, 6, 12, and 18mo.

RESULTS

Totally 32 eyes of 32 patients aged over 26y with progressive keratoconus underwent PFPL M Epi-On ACXL were included. All groups demonstrated long-term stability in UDVA and CDVA. The 10 J/cm2 group showed the greatest improvement in CDVA (+0.17 decimal), significant corneal flattening (Kmax reduction: -1.03 D), and the most substantial HOAs reduction (-0.30 µm). No significant differences were observed between the 7.2 and 8.6 J/cm2 groups. OCT showed fluence-dependent demarcation line depths: 250±30 µm in the 10 J/cm2 group. No adverse events were observed.

CONCUSION: PFPL M Epi-On ACXL appears to be a safe, repeatable, and effective long-term treatment for progressive keratoconus. The 10 J/cm2 fluence is associated with better optical and structural outcomes compared with lower fluences. Consistency in protocol application is essential to ensure efficacy.

Для цитирования: Ferrise Marco, Gagliano Caterina, D'Esposito Fabiana, Cappellani Francesco, Zagari Marco, Mazzotta Cosimo. Efficacy and safety of progressive fluence pulsed light epithelium-on accelerated corneal cross-linking for progressive keratoconus: 18-month prospective results.. International journal of ophthalmology. 2026. DOI: 10.18240/ijo.2026.07.09.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.