MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0284185120916202

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2020

Dual-energy CT to differentiate gallbladder polyps: cholesterol versus adenomatous.

Yin Sheng Nan, Chi Jing, Liu Li, Ding Ning, Ji Yi Ding, Yuan Jian Mao

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Dual-energy computed tomography (DE-CT) scans were acquired to identify cholesterol and adenomatous gallbladder (GB) polyps, which have not been well evaluated before surgery.

PURPOSE: To evaluate the DE-CT findings of GB polyps 1.0-2.0 cm in size and differentiate between cholesterol and adenomatous polyps.

MATERIAL AND

METHODS

Forty-six patients with GB polyps were surgically treated from December 2017 to December 2019 and divided into two groups according to their postoperative pathologic results: a cholesterol group with 26 patients and an adenomatous group with 20 patients. All of these patients underwent DE-CT imaging with tube voltages of 80 kVp and 140 kVp within two weeks before surgery. Mean attenuation values were measured for every GB polyp at 80/140 kVp and at 40/140 keV. The mean attenuation value changes between 140 kVp and 80 kVp (MAVC140-80 kVp) and mean attenuation value changes between 100 keV and 40 keV (MAVC100-40 keV) were calculated.

RESULTS

The CT image parameters of all 46 patients with GB polyps were analyzed. There were significant differences in MAVC140-80 kVp and MAVC100-40 keV between cholesterol and adenomatous polyps (P <0.05); these values were positive for cholesterol polyps and negative for adenomatous polyps.

CONCLUSION

The unique energy spectrum information provided by DE-CT scans is helpful in differentiating between cholesterol and adenomatous polyps 1.0-2.0 cm in size.

Для цитирования: Yin Sheng Nan, Chi Jing, Liu Li, Ding Ning, Ji Yi Ding, Yuan Jian Mao. Dual-energy CT to differentiate gallbladder polyps: cholesterol versus adenomatous.. Acta radiologica (Stockholm, Sweden : 1987). 2020. DOI: 10.1177/0284185120916202.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.