m+Medelevator.RU
← Поиск публикаций
The European respiratory journal · 2026

Shear-wave elastography-guided transthoracic biopsy for lung lesions: a randomised controlled trial.

СтатьяРандомизированное исследованиеPragmatic Clinical TrialНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kuo Yao-Wen, Chen Yen-Lin, Chen Yung-Hsuan, Chang Yih-Leong, Jan I-Shiow, Wu Chen-Tu, Hsieh Min-Shu, Huang Chun-Kai, Wu Huey-Dong, Fang Chi-Tai, Wang Hao-Chien

Аннотация

BACKGROUND: Transthoracic shear-wave elastography (SWE) facilitates differentiation between benign and malignant lesions. This pragmatic randomised controlled trial aimed to validate the effectiveness and safety of SWE-guided transthoracic biopsy for diagnosing subpleural lung lesions.

METHODS: Eligible patients with peripheral lung lesions suspicious for lung malignancy and suitable for biopsy were randomised in a 1:1 ratio to the SWE-guided or conventional ultrasound-guided transthoracic biopsy groups. Rapid on-site cytological evaluations were performed to guide adjustments to biopsy target areas. The primary outcome was the diagnostic yield, defined as the proportion of biopsies yielding a specific benign or malignant diagnosis on cytology or histology. Secondary outcomes included biopsy duration and the combined incidence of post-biopsy complications.

RESULTS: From May 2019 to June 2023, a total of 413 patients were randomised. Ultimately, 205 patients in the SWE group and 206 in the conventional group were included in the intention-to-diagnose analysis. The SWE group achieved a significantly higher diagnostic yield compared with the conventional group (94.6% versus 88.3%; risk ratio 1.07, 95% CI 1.01-1.14; p=0.02) and a shorter biopsy duration (median (interquartile range) 12 (9-15) versus 13 (10-18) min; Hodges-Lehmann median difference -1.0 (95% CI -3.0-0) min; p=0.003). The combined incidence of pneumothorax, haemoptysis and haemothorax was comparable between the groups (2.4% versus 2.9%; risk ratio 0.84, 95% CI 0.26-2.70; p=0.77).

CONCLUSIONS: SWE-guided transthoracic biopsy increased the diagnostic yield and reduced the biopsy duration for subpleural lung lesions without increasing the risk of complications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты