MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijrobp.2023.12.032

Медицинская библиотека · International journal of radiation oncology, biology, physics · 2024

Exploring Deep Learning for Estimating the Isoeffective Dose of FLASH Irradiation From Mouse Intestinal Histological Images.

Fu Jie, Yang Zi, Melemenidis Stavros, Viswanathan Vignesh, Dutt Suparna, Manjappa Rakesh, Lau Brianna, Soto Luis A, Ashraf M Ramish, Skinner Lawrie, Yu Shu-Jung, Surucu Murat, Casey Kerriann M, Rankin Erinn B, Graves Edward, Lu Weiguo, Loo Billy W, Gu Xuejun

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: Ultrahigh-dose-rate (FLASH) irradiation has been reported to reduce normal tissue damage compared with conventional dose rate (CONV) irradiation without compromising tumor control. This proof-of-concept study aims to develop a deep learning (DL) approach to quantify the FLASH isoeffective dose (dose of CONV that would be required to produce the same effect as the given physical FLASH dose) with postirradiation mouse intestinal histology images.

METHODS AND MATERIALS: Eighty-four healthy C57BL/6J female mice underwent 16 MeV electron CONV (0.12 Gy/s; n = 41) or FLASH (200 Gy/s; n = 43) single fraction whole abdominal irradiation. Physical dose ranged from 12 to 16 Gy for FLASH and 11 to 15 Gy for CONV in 1 Gy increments. Four days after irradiation, 9 jejunum cross-sections from each mouse were hematoxylin and eosin stained and digitized for histological analysis. CONV data set was randomly split into training (n = 33) and testing (n = 8) data sets. ResNet101-based DL models were retrained using the CONV training data set to estimate the dose based on histological features. The classical manual crypt counting (CC) approach was implemented for model comparison. Cross-section-wise mean squared error was computed to evaluate the dose estimation accuracy of both approaches. The validated DL model was applied to the FLASH data set to map the physical FLASH dose into the isoeffective dose.

RESULTS

The DL model achieved a cross-section-wise mean squared error of 0.20 Gy2 on the CONV testing data set compared with 0.40 Gy2 of the CC approach. Isoeffective doses estimated by the DL model for FLASH doses of 12, 13, 14, 15, and 16 Gy were 12.19 ± 0.46, 12.54 ± 0.37, 12.69 ± 0.26, 12.84 ± 0.26, and 13.03 ± 0.28 Gy, respectively.

CONCLUSIONS

Our proposed DL model achieved accurate CONV dose estimation. The DL model results indicate that in the physical dose range of 13 to 16 Gy, the biologic dose response of small intestinal tissue to FLASH irradiation is represented by a lower isoeffective dose compared with the physical dose. Our DL approach can be a tool for studying isoeffective doses of other radiation dose modifying interventions.

Для цитирования: Fu Jie, Yang Zi, Melemenidis Stavros, Viswanathan Vignesh, Dutt Suparna, Manjappa Rakesh, Lau Brianna, Soto Luis A, Ashraf M Ramish, Skinner Lawrie, Yu Shu-Jung, Surucu Murat, Casey Kerriann M, Rankin Erinn B, Graves Edward, Lu Weiguo, Loo Billy W, Gu Xuejun. Exploring Deep Learning for Estimating the Isoeffective Dose of FLASH Irradiation From Mouse Intestinal Histological Images.. International journal of radiation oncology, biology, physics. 2024. DOI: 10.1016/j.ijrobp.2023.12.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.