MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10278-024-01303-7

Медицинская библиотека · Journal of imaging informatics in medicine · 2024

Developing a Reproducible Radiomics Model for Diagnosis of Active Crohn's Disease on CT Enterography Across Annotation Variations and Acquisition Differences.

Chirra Prathyush V, Giriprakash Pavithran, Rizk Alain G, Kurowski Jacob A, Viswanath Satish E, Gandhi Namita S

СтатьяПеревод пока не подготовлен

Аннотация

To systematically identify radiomics features on CT enterography (CTE) scans which can accurately diagnose active Crohn's disease across multiple sources of variation. Retrospective study of CTE scans curated between 2013 and 2015, comprising 164 subjects (65 male, 99 female; all patients were over the age of 18) with endoscopic confirmation for the presence or absence of active Crohn's disease. All patients had three distinct sets of scans available (full and reduced dose, where the latter had been reconstructed via two different methods), acquired on a single scanner at a single institution. Radiomics descriptors from annotated terminal ileum regions were individually and systematically evaluated for resilience to different imaging variations (changes in dose/reconstruction, batch effects, and simulated annotation differences) via multiple reproducibility measures. Multiple radiomics models (by accounting for each source of variation) were evaluated in terms of classifier area under the ROC curve (AUC) for identifying patients with active Crohn's disease, across separate discovery and hold-out validation cohorts. Radiomics descriptors selected based on resiliency to multiple sources of imaging variation yielded the highest overall classification performance in the discovery cohort (AUC = 0.79 ± 0.04) which also best generalized in hold-out validation (AUC = 0.81). Performance was maintained across multiple doses and reconstructions while also being significantly better (p < 0.001) than non-resilient descriptors or descriptors only resilient to a single source of variation. Radiomics features can accurately diagnose active Crohn's disease on CTE scans across multiple sources of imaging variation via systematic analysis of reproducibility measures. Clinical utility and translatability of radiomics features for diagnosis and characterization of Crohn's disease on CTE scans will be contingent on their reproducibility across multiple types and sources of imaging variation.

Для цитирования: Chirra Prathyush V, Giriprakash Pavithran, Rizk Alain G, Kurowski Jacob A, Viswanath Satish E, Gandhi Namita S. Developing a Reproducible Radiomics Model for Diagnosis of Active Crohn's Disease on CT Enterography Across Annotation Variations and Acquisition Differences.. Journal of imaging informatics in medicine. 2024. DOI: 10.1007/s10278-024-01303-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.