MedElevator Войти в исследования
← Поиск публикаций

DOI 10.11607/jomi.7657

Медицинская библиотека · The International journal of oral & maxillofacial implants · 2019

The Critical Peri-implant Buccal Bone Wall Thickness Revisited: An Experimental Study in the Beagle Dog.

Monje Alberto, Chappuis Vivianne, Monje Florencio, Muñoz Fernando, Wang Hom-Lay, Urban Istvan A, Buser Daniel

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: There is a lack of knowledge concerning the critical buccal bone thickness required for securing favorable functional and esthetic outcomes, conditioned to the dimensional changes after implant placement. A preclinical study was therefore carried out to identify the critical buccal bone wall thickness for minimizing bone resorption during physiologic and pathologic bone remodeling.

MATERIALS AND

METHODS

A randomized, two-arm in vivo study in healthy beagle dogs was carried out. The first group of dogs was sacrificed 8 weeks after implant placement for histomorphometric examination of postsurgical resorption of the buccal bone wall. The second group of dogs was monitored during three ligature-induced peri-implantitis episodes and a spontaneous progression episode. Morphometric and clinical variables were defined for the study of physiologic and pathologic buccal and lingual bone loss.

RESULTS

Seventy-two implants were placed in healed mandibular ridges of 12 beagle dogs. Two groups were defined: 36 implants were placed in sites with a thin buccal bone wall (< 1.5 mm), and 36 were placed in sites with a thick buccal bone wall (≥ 1.5 mm). No implants failed during the study period. For the great majority of the histomorphometric parameters, a critical buccal bone wall thickness of at least 1.5 mm seemed to be essential for maintaining the buccal bone wall during physiologic and pathologic bone resorption. Suppuration (+) and mucosal recession (-) were more often associated with implants placed in sites with a thin buccal bone wall.

CONCLUSION

A critical buccal bone wall thickness of 1.5 mm at implant placement is advised, since a thicker peri-implant buccal bone wall (> 1.5 mm) is exposed to significantly less physiologic and pathologic bone loss compared with a thinner buccal bone wall (< 1.5 mm).

Для цитирования: Monje Alberto, Chappuis Vivianne, Monje Florencio, Muñoz Fernando, Wang Hom-Lay, Urban Istvan A, Buser Daniel. The Critical Peri-implant Buccal Bone Wall Thickness Revisited: An Experimental Study in the Beagle Dog.. The International journal of oral & maxillofacial implants. 2019. DOI: 10.11607/jomi.7657.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.