The prototype DynamiX camera system - a high-frame-rate high-dynamic-range hard X-ray integrating detector for fourth-generation synchrotrons.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Knowles Simon, Ballard Darren, Banks Dominic, Bell Stephen, Bettelli Manuele, Church Ivan, Dainty Alex, Davis Adam, Dhamgaye Vishal, Fox Oliver, French Marcus, Gardiner Thomas, Ghorbanian Navid, Harris Josh, Hart Matt, Koorikkat Aswathi, Larkin Matt, Lipp John, Matheson John, Nicholls Tim, Nobes Joseph, Prydderch Mark, Sawhney Kawal, Veale Matthew C, Wilson Matthew D, Zanettini Silvia

Аннотация

The development of fourth-generation synchrotrons, including the Diamond-II upgrade, promises 10-100× flux increases, reaching up to 1012 photons s-1 mm-2 at the detector, across a broad range of energies from 20 to 100 keV. To exploit fully these impressive photon fluxes and high X-ray energies, readout chips must achieve high frame rates and dynamic ranges, while the use of high-Z sensor materials is essential. To address these challenges, the UK's Science and Technology Facilities Council has developed DynamiX, a test structure for a novel two-stage charge cancellation circuit on a 65 nm CMOS process with a dynamic range from single photon(s) per pixel per frame to >9000 photons per pixel per frame (1011-1012 photons s-1 mm-2) at 20 keV photon energy. The application-specific integrated circuit has 16 ×16 pixels on 110 µm pitch and is hybridized with 2 mm thick Redlen high-flux cadmium zinc telluride (HF-CdZnTe). Data are read out at 534000 frames per second over a 14 Gbps serialiser and frames are assembled and saved with a custom data acquisition system. Measurements were made on the Diamond Light Source (DLS) B16 Test Beamline using monochromatic X-ray beams of different sizes and energies to evaluate the detector performance. A sub-pixel beam of size ∼60 µm × ∼15 µm was used to probe pixels to measure single photons with a noise performance of σ = 5.7 ± 0.1 keV. These single photons are used to calibrate the test pulse and pixel cancellation packet sizes. The linearity of the detector response under increasing flux was measured from <1 photon per pixel per frame to ∼109 photons s-1 mm-2 at 20 keV with an r.m.s. linearity of 6.2%. A polychromatic X-ray set was used to reach higher fluxes of ∼3 × 1010 photons s-1 mm-2 (20 keV equivalent), yielding an r.m.s. linearity of 3.2%. Finally, the full sensor area was used to image a rotating slitted disc at 534000 frames per second.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты