MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jim.2015.05.001

Медицинская библиотека · Journal of immunological methods · 2015

Application of salivary antibody immunoassays for the detection of incident infections with Norwalk virus in a group of volunteers.

Griffin Shannon M, Converse Reagan R, Leon Juan S, Wade Timothy J, Jiang Xi, Moe Christine L, Egorov Andrey I

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

Norovirus infection is the most common cause of acute gastroenteritis in developed countries. Developing an assay based on a non-invasive biomarker for detecting incident norovirus infections could improve disease surveillance and epidemiological investigations. This project involved analysis of IgA and IgG norovirus-specific antibody responses in saliva samples from a Norwalk virus (Genogroup I, genotype 1 norovirus) challenge study involving infected and symptomatic, and non-infected asymptomatic individuals. Saliva was collected at the challenge, and two weeks and 40 days post-challenge. Samples were analyzed using the Luminex fluorometric and Meso Scale Discovery (MSD) electrochemiluminescence immunoassays. Recombinant P domains of Norwalk virus capsid protein, as well as similar recombinant proteins of two genogroup II noroviruses (VA387 and VA207) were used as antigens. Immunoconversions were defined as >4-fold increase in antibody responses to the norovirus antigens. Various sample pre-treatment options, buffers, saliva dilution ratios, and data adjustment approaches to control for sample-to-sample variability in saliva composition were compared using the Luminex assay. The results suggest that adjusting responses to the norovirus antigens for responses to the protein purification tag, glutathione-S-transferase (GST), significantly improved the odds of producing a correct immunoconversion test result. IgG-based tests were more accurate compared to IgA-based tests. At optimal conditions, both Luminex and MSD assays for Norwalk-specific IgG antibodies correctly identified all infected and non-infected individuals. There was no evidence of cross-reactivity of anti-Norwalk virus antibodies with genogroup II noroviruses. These results suggest that salivary antibody responses can be used for the detection of incident infections with Norwalk virus in prospective surveys.

Для цитирования: Griffin Shannon M, Converse Reagan R, Leon Juan S, Wade Timothy J, Jiang Xi, Moe Christine L, Egorov Andrey I. Application of salivary antibody immunoassays for the detection of incident infections with Norwalk virus in a group of volunteers.. Journal of immunological methods. 2015. DOI: 10.1016/j.jim.2015.05.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.