Journal of the American College of Cardiology · 2003

Effect of percutaneous coronary interventions for in-stent restenosis in degenerated saphenous vein grafts without distal embolic protection.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ashby Dale T, Dangas George, Aymong Eve A, Iakovou Ioannis, Kuepper Frank, Mehran Roxana, Stone Gregg W, Leon Martin B, Moses Jeffery W

Аннотация

OBJECTIVES: This study was designed to investigate the impact of percutaneous coronary interventions (PCIs) in degenerated saphenous vein grafts (SVGs) without distal embolic protection.

BACKGROUND: Distal embolic protection devices have been shown to reduce the incidence of no reflow/slow flow during PCI of de novo lesions in degenerated SVGs. It is unclear whether PCI of in-stent restenosis (ISR) lesions in degenerated SVGs is associated with no reflow/slow flow and whether distal embolic protection is beneficial in these cases as well.

METHODS: We studied 54 consecutive patients with treated ISR lesions in degenerated SVGs who underwent PCI without distal embolic protection in a single center. Procedural and in-hospital outcomes were examined. The average age was 71 +/- 8 years; 32% of the patients had diabetes. The mean lesion length was 13 +/- 6 mm and the procedural success rate was 98% (53/54). Cutting balloon angioplasty was used in 46% (25/54) of cases, and a new stent was inserted in 46% (25/54) of patients. Gamma brachytherapy was performed in 19% (10/54) of patients. During the procedure there were no episodes of no reflow/slow flow, and there were no patients with in-hospital Q-wave or non-Q-wave myocardial infarction. There was one in-hospital noncardiac death.

CONCLUSIONS: In this consecutive series of patients with ISR of degenerated SVGs undergoing PCI without distal protection, there were no episodes of slow flow/no reflow and no procedure-related myocardial infarctions. It appears that distal embolic protection may not be necessary during PCI of ISR lesions in degenerated SVGs.

Предметные рубрики MeSH