MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0735-1097(02)02129-0

Медицинская библиотека · Journal of the American College of Cardiology · 2002

Distal filter protection during saphenous vein graft stenting: technical and clinical correlates of efficacy.

Stone Gregg W, Rogers Campbell, Ramee Steve, White Christopher, Kuntz Richard E, Popma Jeffrey J, George John, Almany Steve, Bailey Steve

Клиническое исследованиеКлиническое исследование II фазыСравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАОбзорПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to evaluate the clinical, angiographic, and technical factors related to successful stenting of diseased saphenous vein grafts (SVGs) using a novel filter-based distal protection device.

BACKGROUND

Protection of the distal microvasculature with a balloon occlusion and aspiration system has been shown to reduce atherothrombotic embolization and peri-procedural myocardial infarction (MI) after percutaneous coronary intervention (PCI) in SVGs. The safety, efficacy, and technical factors relating to procedural success with filter-based distal protection devices are unknown.

METHODS

Percutaneous coronary intervention was performed in 60 lesions in 48 patients undergoing SVG intervention with the FilterWire EX distal protection system in a phase I experience at six sites. A larger phase II study was then performed in 248 lesions in 230 SVGs at 65 U.S. centers.

RESULTS

Cumulative adverse events to 30 days occurred in 21.3% of patients in phase I, including a 19.1% rate of MI. Numerous anatomic, device-specific, and operator-related contributors to these adverse events were identified, resulting in significant changes to the protocol and instructions for use. Subsequently, despite similar clinical and angiographic characteristics to the phase I patients, the 30-day adverse event rate in phase II was reduced to 11.3% (p = 0.09), due primarily to a lower incidence of peri-procedural Q-wave and non-Q-wave MI.

CONCLUSIONS

Distal protection during SVG PCI with the FilterWire EX is associated with a low rate of peri-procedural adverse events compared to historical controls. A unique set of anatomic, technical, and operator-related issues exist with distal filters which, if ignored, may reduce their effectiveness.

Для цитирования: Stone Gregg W, Rogers Campbell, Ramee Steve, White Christopher, Kuntz Richard E, Popma Jeffrey J, George John, Almany Steve, Bailey Steve. Distal filter protection during saphenous vein graft stenting: technical and clinical correlates of efficacy.. Journal of the American College of Cardiology. 2002. DOI: 10.1016/s0735-1097(02)02129-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.