DOI 10.1016/j.jacep.2025.09.010
Risk Stratification in Left Bundle Branch Block After Transcatheter Aortic Valve Implantation: A Multicenter ECG Algorithm Study.
Аннотация
BACKGROUND
Managing left bundle branch block (LBBB) after transcatheter aortic valve implantation (TAVI) remains challenging.
OBJECTIVES
The aim of this study was to develop a novel, simplified electrocardiogram (ECG) algorithm for predicting infranodal conduction delay in LBBB (both new onset as well as preexisting) patients after TAVI and to compare its performance vs current European Society of Cardiology (ESC) ECG criteria.
METHODS
A multicenter analysis of prospectively enrolled patients undergoing electrophysiology testing for preexisting or new-onset LBBB after TAVI was conducted. The novel algorithm was developed by analyzing various combinations of the PR interval, QRS duration pre-TAVI and post-TAVI, and changes in these parameters to identify patients with infranodal conduction delay (defined as a His-ventricular interval ≥70 milliseconds).
RESULTS
A total of 769 patients with LBBB (12% preexisting) after TAVI underwent risk stratification using electrophysiology testing at 7 institutions (mean age 81 ± 7 years; 57% female; 21% His-ventricular ≥70 milliseconds). A novel algorithm using solely a PR interval of 190 milliseconds and a QRS interval of 160 milliseconds revealed a sensitivity of 88% and an negative predictive value of 92% for the rule-out of infranodal conduction delay (PR interval post-TAVI <190 milliseconds AND QRS duration post-TAVI <160 milliseconds) and a specificity and positive predictive value of 85% and 41%, respectively, for the rule-in of infranodal conduction delay (PR interval post-TAVI ≥190 milliseconds AND QRS duration post-TAVI ≥160 milliseconds). By comparison, the ESC ECG criteria showed a sensitivity of 72%, a negative predictive value of 88%, specificity of 53%, and a positive predictive value of 28%.
CONCLUSIONS
The novel, simplified ECG algorithm showed a superior performance for the rule-out and rule-in of infranodal conduction delay compared with current ESC ECG criteria.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.