MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.shj.2025.100726

Медицинская библиотека · Structural heart : the journal of the Heart Team · 2025

Preprocedural CT and ECG Markers for Predicting Post-TAVR Pacemaker Requirement in High-Risk Patients.

Tretter Justin T, Eleid Mackram F, Bedogni Francesco, Rodés-Cabau Josep, Regueiro Ander, Testa Luca, Chen Shmuel, Galhardo Attilio, Ellenbogen Kenneth A, Leon Martin B, Ben-Haim Shlomo

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Need for permanent pacemaker implantation (PPI) following transcatheter aortic valve replacement (TAVR) remains a common complication. We aimed to assess computed tomography (CT)-based anatomical and electrocardiogram (ECG)-based parameters in a predictive model for PPI following TAVR.

METHODS

We assessed CT-based parameters, including the predicted course of the conduction axis from atrioventricular node to left bundle branch origin relative to the aortic virtual basal ring. Electrophysiological variables were combined in assessing a model to predict post-TAVR PPI.

RESULTS

Among 433 patients (mean age 82.0 [9.0] years, 54.0% female), 90 (21.0%) required PPI. Multiple binary logistic modeling demonstrated a shallower position of the membranous septum inferior margin midpoint increased the odds of PPI by 20% for every 1 mm (adjusted odds ratio [aOR]: 1.20) adjusted for the CT assessment phase. Increasing aortic root rotational angle associated with lower PPI odds (odds ratio [OR]: 0.98; 95% CI [0.95-1.00]), while an angle between the membranous septum midpoint and noncoronary leaflet nadir associated with increased PPI odds (OR: 1.04; 95% CI [1.01-1.08]). Preprocedural right bundle branch block and first-degree atrioventricular block associated with increased odds for PPI (OR: 3.76; 95% CI [1.71-8.21]; and OR: 1.84; 95% CI [1.06-3.18], respectively). The model had an area under the curve of 0.73 (95% CI [0.67-0.79]), sensitivity of 0.74 (95% CI [0.47-0.93]), and specificity of 0.65 (95% CI [0.40-0.87]) for predicting PPI requirement.

CONCLUSIONS

A predictive model for determining the risk of PPI following TAVR is reported, combining comprehensive conduction-specific anatomical measurements relative to the aortic root and electrical measurements with clinical parameters. This model requires prospective application to understand its performance in the real-world.

Для цитирования: Tretter Justin T, Eleid Mackram F, Bedogni Francesco, Rodés-Cabau Josep, Regueiro Ander, Testa Luca, Chen Shmuel, Galhardo Attilio, Ellenbogen Kenneth A, Leon Martin B, Ben-Haim Shlomo. Preprocedural CT and ECG Markers for Predicting Post-TAVR Pacemaker Requirement in High-Risk Patients.. Structural heart : the journal of the Heart Team. 2025. DOI: 10.1016/j.shj.2025.100726.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.