Patient-specific three-dimensional dose distribution prediction via deep learning for prostate cancer therapy: Improvement with the structure loss.

Koike Yuhei, Takegawa Hideki, Anetai Yusuke, Ohira Shingo, Nakamura Satoaki, Tanigawa Noboru

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Deep learning (DL)-based dose distribution prediction can potentially reduce the cost of inverse planning process. We developed and introduced a structure-focused loss (Lstruct) for 3D dose prediction to improve prediction accuracy. This study investigated the influence of Lstruct on DL-based dose prediction for patients with prostate cancer. The proposed Lstruct, which is similar in concept to dose-volume histogram (DVH)-based optimization in clinical practice, has the potential to provide more interpretable and accurate DL-based optimization.

METHODS

This study involved 104 patients who underwent prostate radiotherapy. We used 3D U-Net-based architecture to predict dose distributions from computed tomography and contours of the planning target volume and organs-at-risk. We trained two models using different loss functions: L2 loss and Lstruct. Predicted doses were compared in terms of dose-volume parameters and the Dice similarity coefficient of isodose volume.

RESULTS

DVH analysis showed that the Lstruct model had smaller errors from the ground truth than the L2 model. The Lstruct model achieved more consistent dose distributions than the L2 model, with errors close to zero. The isodose Dice score of the Lstruct model was greater than that of the L2 model by >20% of the prescribed dose.

CONCLUSIONS

We developed Lstruct using labels of inputted contours for DL-based dose prediction for prostate radiotherapy. Lstruct can be generalized to any DL architecture, thereby enhancing the dose prediction accuracy.

Для цитирования: Koike Yuhei, Takegawa Hideki, Anetai Yusuke, Ohira Shingo, Nakamura Satoaki, Tanigawa Noboru. Patient-specific three-dimensional dose distribution prediction via deep learning for prostate cancer therapy: Improvement with the structure loss.. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 2023. DOI: 10.1016/j.ejmp.2023.102544.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.