MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-023-09390-w

Медицинская библиотека · European radiology · 2023

Accuracy and reproducibility of a cone beam CT-based virtual parenchymal perfusion algorithm in the prediction of SPECT/CT anatomical and volumetric results during the planification of radioembolization for HCC.

Derbel Haytham, Krichen Mahdi, Chalaye Julia, Saccenti Laetitia, Van der Sterren William, Muris Anne-Hilde, Lerman Lionel, Galletto Athena, Zaarour Youssef, Luciani Alain, Kobeiter Hicham, Tacher Vania

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate anatomical and volumetric predictability of a cone beam computed tomography (CBCT)-based virtual parenchymal perfusion (VPP) software for the single-photon-emission computed tomography (SPECT)/CT imaging results during the work-up for transarterial radioembolization (TARE) procedure in patients with hepatocellular carcinoma (HCC).

METHODS

VPP was evaluated retrospectively on CBCT data of patients treated by TARE for HCC. 99mTc macroaggregated albumin particles (99mTc-MAA) uptake territories on work-up SPECT/CT was used as ground truth for the evaluation. Semi-quantitative evaluation consisted of the ranking of visual consistency of the parenchymal enhancement and portal vein tumoral involvement on VPP and 99mTc-MAA SPECT/CT, using a three-rank scale and two-rank scale, respectively. Inter-reader agreement was evaluated using a kappa coefficient. Quantitative evaluation included absolute volume error calculation and Pearson correlation between volumes enhanced territories on VPP and 99mTc-MAA SPECT/CT.

RESULTS

Fifty-two CBCTs were performed in 33 included patients. Semi-quantitative evaluation showed a good concordance between actual 99mTc-MAA uptake and the virtual enhanced territories in 73% and 75% of cases; a mild concordance in 12% and 10% and a poor concordance in 15%, for the two readers. Kappa coefficient was 0.86. Portal vein involvement evaluation showed a good concordance in 58.3% and 66.7% for the two readers, respectively, with a kappa coefficient of 0.82. Quantitative evaluation showed a volume error of 0.46 ± 0.78 mL [0.01-3.55], and Pearson R2 factor at 0.75 with a p value < 0.01.

CONCLUSION

CBCT-based VPP software is accurate and reliable to predict 99mTc-MAA SPECT/CT anatomical and volumetric results in HCC patients during TARE.

KEY POINTS: • Virtual parenchymal perfusion (VPP) software is accurate and reliable in the prediction of 99mTc-MAA SPECT volumetric and targeting results in HCC patients during transarterial radioembolization (TARE). • VPP software may be used per-operatively to optimize the microcatheter position for 90Y infusion allowing precise tumor targeting while preserving non-tumoral parenchyma. • Post-operatively, VPP software may allow an accurate estimation of the perfused volume by each arterial branch and, thus, a precise 90Y dosimetry for TARE procedures.

Для цитирования: Derbel Haytham, Krichen Mahdi, Chalaye Julia, Saccenti Laetitia, Van der Sterren William, Muris Anne-Hilde, Lerman Lionel, Galletto Athena, Zaarour Youssef, Luciani Alain, Kobeiter Hicham, Tacher Vania. Accuracy and reproducibility of a cone beam CT-based virtual parenchymal perfusion algorithm in the prediction of SPECT/CT anatomical and volumetric results during the planification of radioembolization for HCC.. European radiology. 2023. DOI: 10.1007/s00330-023-09390-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.