BACKGROUND AND PURPOSE: To establish an international quality standard for contouring and planning for high-risk neuroblastoma within the prospective High-Risk Neuroblastoma Study 2 of SIOP-Europe-Neuroblastoma (SIOPEN HR-NBL2), which includes a randomized question on dose escalation for residual disease.

MATERIALS AND

METHODS

Data on four patients with high-risk neuroblastoma were selected and distributed to the radiotherapy committee of the HR-NBL2 study for independent contouring and planning. Differences in contouring were analyzed using apparent and kappa-corrected agreement. Plans were analyzed regarding the dose-volume histogram metrics. Results were discussed among experts and agreement was obtained.

RESULTS

Substantial agreement was found for contouring of the heart (0.64), liver (0.70), left lung (0.74), and right lung (0.74). For contouring of the gastrointestinal tract (0.54), left kidney (0.60), and right kidney (0.59) moderate agreement was obtained. For target volume delineation, agreement for preoperative tumour extent was moderate (0.42), for CTV fair (0.35) and only low (0.06) for residual tumour, respectively. The dose planning strategies appeared to be relatively homogeneous among all experts.

CONCLUSION

Considerable variability was found for the delineation of target volumes, particularly the boost volume, whereas the contouring of the organs at risk and the planning strategy were reasonably consistent. In order to obtain reliable results from the randomized HR-NBL2 trial, standardization of target volume delineation based on adequate imaging is crucial.

Для цитирования: Jazmati Danny, Brualla Lorenzo, Littooij Annemieke S, Webber Britta, Dieckmann Karin, Janssens Geert O, Simon Thorsten, Gaze Mark N, Merta Julien, Serrano Antonio, Dietzsch Stefan, Kramer Paul-Heinz, Wulff Jörg, Boterberg Tom, Timmermann Beate. Overcoming inter-observer planning variability in target volume contouring and dose planning for high-risk neuroblastoma - a European multicenter effort of the SIOPEN radiotherapy committee.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2023. DOI: 10.1016/j.radonc.2023.109464.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.