Navigator-triggered and breath-hold 3D MRCP using compressed sensing: image quality and method selection factor assessment.

Morimoto Daisuke, Hyodo Tomoko, Kamata Ken, Kadoba Tomoya, Itoh Makoto, Fukushima Hiroyuki, Chiba Yasutaka, Takenaka Mamoru, Mochizuki Tomohiro, Ueda Yu, Miyagoshi Keizou, Kudo Masatoshi, Ishii Kazunari

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To examine whether MRCP using a combination of compressed sensing and sensitivity encoding with navigator-triggered and breath-hold techniques (NT C-SENSE and BH C-SENSE, respectively) have comparable image quality to that of navigator-triggered MRCP using only sensitivity encoding (NT SENSE) at 1.5-T.

METHODS

Fifty-one participants were enrolled in this prospective study between July and October 2018 and underwent the three 3D MRCP sequences each. The acquisition time and relative duct-to-periductal contrast ratios (RC values) of each bile duct segment were obtained. Visualization of the bile and main pancreatic ducts, background suppression, artifacts, and overall image quality were scored on 5-point scales. Mean and median differences in RC values and qualitative scores of NT C-SENSE and BH C-SENSE relative to NT SENSE were calculated with 95% confidence intervals (CIs).

RESULTS

Acquisition time of NT SENSE, NT C-SENSE, and BH C-SENSE were 348, 143 (mean for both), and 18 s (for all participants), respectively. The RC value of each bile duct segment was inferior, but the lower limits of the 95% CIs of the mean differences were ≥ - 0.10, for both NT C-SENSE and BH C-SENSE. The visualization score of the intrahepatic duct in BH C-SENSE was inferior to that in NT SENSE (lower 95% CI limit, - 1.5). In both NT C-SENSE and BH C-SENSE, the 95% CIs of the median differences in the other qualitative scores were from - 1.0 to 0.0.

CONCLUSION

NT C-SENSE and BH C-SENSE have comparable image quality to NT SENSE at 1.5-T.

Для цитирования: Morimoto Daisuke, Hyodo Tomoko, Kamata Ken, Kadoba Tomoya, Itoh Makoto, Fukushima Hiroyuki, Chiba Yasutaka, Takenaka Mamoru, Mochizuki Tomohiro, Ueda Yu, Miyagoshi Keizou, Kudo Masatoshi, Ishii Kazunari. Navigator-triggered and breath-hold 3D MRCP using compressed sensing: image quality and method selection factor assessment.. Abdominal radiology (New York). 2020. DOI: 10.1007/s00261-020-02403-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.