Clinical trial of junction seals for the prevention of urinary catheter-associated bacteriuria.
Аннотация
BACKGROUND
Preconnected catheter systems with sealed junctions have been associated with reduced rates of bacteriuria and mortality. A clinical trial was undertaken to evaluate the effectiveness of a junction seal applied after catheter insertion for preventing bacteriuria and reducing mortality.
METHODS
Patients undergoing transurethral catheterization at a community hospital were randomized within 24 hours of catheter insertion to receive either a tape seal applied to the catheter-drainage tubing junction or no tape seal. Catheter urine cultures and catheter care violations were monitored daily until catheter removal or patient discharge.
RESULTS
Overall, 124 (13.7%) of 903 patients in the group receiving a junction seal acquired bacteriuria, compared with 125 (14.9%) of 837 patients in the control group (P = .52, odds ratio = 0.91, 95% confidence interval, 0.69 to 1.20). Multivariate analysis revealed that only female gender and lack of systemic antibiotic use independently correlated with the development of bacteriuria; neither junction treatment randomization nor disconnection of the junction was associated with bacteriuria. Survival curve analysis of patients stratified by gender and antibiotic use revealed no significant differences in the rate of bacteriuria between treatment groups. The overall mortality in the tape seal group was less than that in the control group (6.6% vs. 8.0%, respectively), but not to a statistically significant extent despite stratification by antibiotic use.
CONCLUSIONS
The use of a tape seal applied to the catheter-drainage tubing junction within 24 hours of catheter insertion was not associated with significantly lower rates of bacteriuria and mortality in patients undergoing short-term catheterization.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.