MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1542-4758.2011.00595.x

Медицинская библиотека · Hemodialysis international. International Symposium on Home Hemodialysis · 2011

Use of ionic dialysance to calculate Kt/V in pediatric hemodialysis.

Marsenic Olivera, Booker Kristi, Studnicka Kathleen, Wilson Donna, Beck Ann, Swanson Tiffany, Henry Dwayne, Turman Martin

СтатьяПеревод пока не подготовлен

Аннотация

Online clearance (OLC) monitor measures conductivity difference between dialysate entering and leaving the dialyser. Derived ionic dialysance (ID) represents effective urea clearance from which Kt/V is calculated, allowing Kt/V monitoring at every treatment without blood sampling. We tested ID accuracy in children and provide recommendations for its use. Using Fresenius machines 2008 K with built-in OLC monitors, we studied 45 hemodialysis (HD) sessions and 168 calculated Kt/V results in 11 patients. Urea distribution volume (V), needed to calculate Kt/V from ID, was estimated using three methods: Mellits and Cheek (MC), KDOQI recommended total body water nomograms (TBWN) and OLC-derived independent from tested HD sessions. Reference spKt/V from pre- and post-HD BUN (Daugirdas) was compared with Kt/V calculated from ID using three different estimated V's. ID was accurate in calculating Kt/V in children when V derived from OLC was used (P = 0.42), with absolute error 0.14 ± 0.12. If TBWN-derived V was used, Kt/V was consistently underestimated by 0.32 ± 0.22. TBWN-derived V can still be recommended for use with OLC for monitoring trend in Kt/V, if underestimation of spKt/V of average 0.3 is accounted for. MC-derived V results in even greater underestimation of spKt/V and therefore cannot be recommended for use with OLC.

Для цитирования: Marsenic Olivera, Booker Kristi, Studnicka Kathleen, Wilson Donna, Beck Ann, Swanson Tiffany, Henry Dwayne, Turman Martin. Use of ionic dialysance to calculate Kt/V in pediatric hemodialysis.. Hemodialysis international. International Symposium on Home Hemodialysis. 2011. DOI: 10.1111/j.1542-4758.2011.00595.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.