Influence of the Dimensions of the Antrostomy on Osseointegration of Mini-implants Placed in the Grafted Region After Sinus Floor Elevation: A Randomized Clinical Trial.
Аннотация
PURPOSE: To evaluate the osseointegration of mini-implants placed in grafted sinuses with lateral windows of two different dimensions.
MATERIALS AND
METHODS
Sinus floor augmentation was performed in volunteers using a lateral window. The antrostomy was systematically prepared with a height of either 8 mm (large group) or 4 mm (small group). After 6 months of healing, mini-implants were placed in the grafted region. Biopsy specimens including the mini-implants were harvested 3 months after placement.
RESULTS
Twenty biopsy specimens, 10 from each group, were suitable for the histologic analysis. Similar amounts of new bone-to-implant contact were obtained in both the large (41.1% ± 19.5%) and the small (42.8% ± 13.2%) groups (P = .940). Small percentages of residues of xenograft were found in contact with the implant surface, with 0.6% ± 1.1% in the large group and 5.9% ± 9.5% in the small group (P = .098). The new bone density around the implants was 31.7% ± 8.2% and 34.0% ± 7.9% in the large and small groups, respectively (P = .623).
CONCLUSION
The dimensions of the antrostomy did not influence the histologic healing of implants placed 6 months after sinus floor augmentation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.