DOI 10.3389/fcell.2025.1654719
Refractive error after phacoemulsification combined with intraocular lens implantation in primary angle-closure glaucoma: a multifactorial analysis of biometric parameters and surgical strategies.
Аннотация
PURPOSE: This study aims to explore the factors influencing refractive error following Phacoemulsification combined with intraocular lens implantation (PE + IOL) in patients with primary angle-closure glaucoma (PACG), providing a theoretical basis for preoperative consultation and IOL power selection in clinical practice.
METHODS
A retrospective analysis was conducted on 404 PACG patients from Shenzhen Eye Hospital between 2019 and 2024. Preoperative ocular biometric parameters and combined surgical approaches were evaluated using Spearman correlation, multinomial logistic regression, and receiver operating characteristic (ROC) curve analysis.
RESULTS
Axial length (AL), lens thickness (LT), and white-to-white distance (WTW) were key predictive factors for prediction error and postoperative refractive outcomes. AL > 22.56 mm (AUC = 0.692) and LT > 5.055 mm (AUC = 0.633) increased the risk of myopic shift (MS), while AL < 22.25 mm (AUC = 0.604) and WTW <11.55 mm (OR = 2.209, P = 0.001) were associated with hyperopic shift (HS). The axial length/corneal radius (AL/CR) ratio >2.986 further indicated a higher risk of MS (AUC = 0.639) postoperatively. Among patients who underwent PE + IOL combined with capsular tension ring, the proportion of HS was significantly higher (Z value = +2.95).
CONCLUSION
The unique anatomical characteristics of PACG patients are key contributors to postoperative refractive instability. Preoperative assessment for PE + IOL surgery should comprehensively evaluate AL, LT, WTW, and AL/CR ratio. When combined with other surgical approaches to control intraocular pressure, IOL power should be adjusted according to these thresholds to ensure postoperative refractive stability.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.