Аннотация

OBJECTIVE

Recent guidelines for neonatal cardiopulmonary resuscitation emphasize the importance of adequate ventilation. In cases of failed resuscitation with positive pressure ventilation, tracheal intubation and chest compressions are recommended. The present study compared the utility of the Miller laryngoscope (Mil) and the videolaryngoscope Pentax-AWS Airway Scope (AWS; Hoya, Tokyo, Japan) with an infant or neonatal-sized Intlock (AWS-N; Pentax) during chest compressions on a neonatal manikin.

STUDY

DESIGN

A total of 23 novice doctors performed tracheal intubation on a neonatal manikin using the Mil and AWS-N, with or without chest compressions.

RESULTS

In the Mil trials, all participants secured the airway without chest compressions, but nine failed with compressions (p < 0.001). In AWS-N trials, all participants succeeded regardless of whether chest compressions were performed or not. Intubation time was significantly longer with chest compressions with the Mil (p < 0.001), but not with the AWS-N. Laryngoscopy difficulty, as assessed by a visual analog scale (VAS), increased significantly with chest compressions with the Mil, but not with the AWS-N, while the VAS for tube passage through the glottis increased with compressions with the Mil, but not with the AWS-N.

CONCLUSION

The AWS-N is an effective device for endotracheal intubation during chest compressions in neonatal simulations performed by novice doctors.

Для цитирования: Komasawa Nobuyasu, Ueki Ryusuke, Kaminoh Yoshiroh, Nishi Shin-ichi. Comparison of the Miller Laryngoscope and Videolaryngoscope for Tracheal Intubation by Novice Doctors during Neonatal Cardiopulmonary Resuscitation: A Randomized Crossover Simulation Trial.. American journal of perinatology. 2015. DOI: 10.1055/s-0034-1395482.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.