MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0970-9185.117053

Медицинская библиотека · Journal of anaesthesiology, clinical pharmacology · 2013

Assessment of cervical spine movement during laryngoscopy with Macintosh and Truview laryngoscopes.

Bhardwaj Neerja, Jain Kajal, Rao Madhusudan, Mandal Arup Kumar

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Truview laryngoscope provides an indirect view of the glottis and will cause less cervical spine movement since a ventral lifting force will not be required to visualize the glottis compared to Macintosh laryngoscope.

MATERIALS AND

METHODS

A randomized crossover study to assess the degree of movement of cervical spine during endotracheal intubation with Truview laryngoscope was conducted in 25 adult ASA-I patients. After a standard anesthetic technique laryngoscopy was performed twice in each patient using in turn both the Macintosh and Truview laryngoscopes. A baseline radiograph with the head and neck in a neutral position was followed by a second radiograph taken during each laryngoscopy. An experienced radiologist analyzed and measured the cervical movement.

RESULTS

Significant cervical spine movement occurred at all segments when compared to the baseline with both the Macintosh and Truview laryngoscopes (P < 0.001). However, the movement was significantly less with Truview compared to the Macintosh laryngoscope at C0-C1 (21%; P = 0.005) and C1-C2 levels (32%; P = 0.009). The atlantooccipital distance (AOD) traversed while using Truview laryngoscope was significantly less than with Macintosh blade (26%; P = 0.001). Truview blade produced a better laryngoscopic view (P = 0.005) than Macintosh blade, but had a longer time to laryngoscopy (P = 0.04).

CONCLUSION

Truview laryngoscope produced a better laryngoscopic view of glottis as compared with Macintosh laryngoscopy. It also produced significantly less cervical spine movement at C0-C1 and C1-C2 levels than with Macintosh laryngoscope in patients without cervical spine injury and without manual in-line stabilization (MILS). Further studies are warranted with Truview laryngoscope using MILS.

Для цитирования: Bhardwaj Neerja, Jain Kajal, Rao Madhusudan, Mandal Arup Kumar. Assessment of cervical spine movement during laryngoscopy with Macintosh and Truview laryngoscopes.. Journal of anaesthesiology, clinical pharmacology. 2013. DOI: 10.4103/0970-9185.117053.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.