MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-026-02417-4

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026

Safety and feasibility of a balloon-based pulsed field ablation system for the catheter ablation of paroxysmal atrial fibrillation.

Wang Peize, Zhang Kun, Bai Jinlong, Dong Xiuhong, Yang Shuai, Tian Lichao, Zhang Zhaoqian, Li Zhi, Miao Yuhao, Liu Jingjing

СтатьяПеревод в очереди

Аннотация

AIMS: Pulsed field ablation (PFA) is a ablation modality that is increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF) patients. This study assessed the safety and effectiveness of a balloon-based PFA system at 6 months after treatment.

METHODS AND

RESULTS

This study is a prospective, single-center, premarket study. A total of 56 patients with drug-refractory paroxysmal atrial fibrillation (PAF) were enrolled between November 2024 and September 2025 and underwent PVI with a balloon-based PFA system. The study endpoints were the rate of primary serious adverse events, acute procedural effectiveness and 6-month freedom from recurrence. Acute effectiveness was achieved in 100% (231/231) of the treated PVs (100% of patients, 56/56), with 33 ± 5.5 PFA applications/patient. The procedure, fluoroscopy, and transpired ablation times were 89.0 ± 30.7, 24.2 ± 8.3, and 20.0 ± 12.0 min, respectively. One (1.8%; 1/56) primary serious adverse event occurred: one patient developed intraoperative gastrointestinal bleeding due to TEE-induced mechanical injury. One patient developed a cerebral infarction on postoperative Day 28. The rate of freedom from documented atrial arrhythmias was 92.9% through 6 months after the index procedure.

CONCLUSION

The primary results of this study demonstrate the safety and effectiveness of the balloon-based PFA system for performing PVI in patients with PAF.

Для цитирования: Wang Peize, Zhang Kun, Bai Jinlong, Dong Xiuhong, Yang Shuai, Tian Lichao, Zhang Zhaoqian, Li Zhi, Miao Yuhao, Liu Jingjing. Safety and feasibility of a balloon-based pulsed field ablation system for the catheter ablation of paroxysmal atrial fibrillation.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2026. DOI: 10.1007/s10840-026-02417-4.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.